Switches are located on the indoor unit PC board and inside the remote
controller as shown.
Setting the SW1 (PC board inside indoor unit)
Sub-switches 7 or 8 of SW1 can be used as follows to assign a pair No.
The pair No. SW of the remote controller has been set to ‹‹0›› at the time of
ship-ment.
Note:
Make sure that the pair No.
AA
of the remote controller matches that of
the indoor unit PC board.
2-8 Wireless remote controller pair number setting operation
Pair Number
0
1
2
3
Pair NumberSW1 SW1
123456
ON
OFF
78
123456
ON
OFF
78
123456
ON
OFF
78
123456
ON
OFF
78
0
9
8
7
6
5
4
3
2
1
Nrm Set
Reset
After refiling batteries.
Press the reset button.
A
ON/OFF
TEMP
FAN
VANE
MODE
CHECK
LOUVER
TEST RUN
AUTO STOP
AUTO START
h
min
RESET
SET
CLOCK
MODEL SELECT
4
A
Model No.
5
1,4
1 Turn on the main power to the unit.
2 Press the SET button with the point of a ball-point pen or the like.
Start this operation from the status of remote controller display turned off.
blinks and Model No. is lighted.
3 Press the button twice continuously.
A Pair No. “0” blinks.
4 Press the temp button to set the pair number you want to set.
5 Press the SET button with the point of a ball-point pen or the like.
Set pair number is lighted for three seconds then turned off.
MODEL SELECT
min
PK-1.6FLA3, PK-2FLA3
PK-2.5FLA2/3, PK-3FLA2/3/4
PK-4FLSA2/3
PK-2.5FLA4
PK-3FLA5
PK-4FLSA4
A Pair No. of wireless
remote controller
Indoor PC board
< SW1 >
0
1
2
3~9
123456
ON
OFF
78
123456
ON
OFF
78
123456
ON
OFF
78
123456
ON
OFF
78
OC129A-2.qxp 01.10.1 7:33 PM Page 35