Service manual

27
MICROPROCESSOR CONTROL10
TEMP
ON / OFF
NOT AVAILABLE
AM
PM
AM
PM
˚C
1. OUTLINE OF MICROPROCESSOR CONTROL
OFF-ON switching.
COOL • DRY • FAN selector switching.
HIGH-LOW fan speed switching.
TIMER mode selector-switching
Timer setting.
Self diagnostic troubleshooting.
TEST RUN switching.
CHECK mode switching.
AUTO Vane setting.
Room temperature thermistor.
Indoor coil thermistor.
Independent Control of
Outdoor Unit
OUTPUT to indoor unit
INPUT from indoor unit
INPUT to remote controller OUTPUT to remote controller
Indication LCD lights.
12VDC
Indoor unit
Receives orders from remote controller and temperature
data from indoor unit.
Processes orders and data.
Controls indoor and outdoor operation.
Self diagnostic function
w System control operation.<Optional>
w Emergency operation
Fan: ON-OFF.
Fan speed: HIGH-LOW.
AUTO vane’s angle setting.
Emergency stop.
INPUT from outdoor unit
Compressor protection device working.
OUTPUT from outdoor unit
Compressor motor and outdoor fan motor : ON-OFF.
OUTPUT UNIT
Receives orders from
indoor controller.
Emergency stop.
Non-polar, two (2) - core cable
Outdoor unit
INDOOR CONTROLLER BOARD
REMOTE CONTROLLER
Processes and transmits orders.
PK-1.6FLA
3
PK-2FLA3
PK-2.5FLA2/3
PK-3FLA2/3/4
PK-4FLSA2/3
PK-2.5FLA4
PK-3FLA5
PK-4FLSA4