Specs

Model Number
Indoor Unit PEAD-A30AA7
Outdoor Unit
PUY-A30NHA7
PUY-A30NHA7-BS
Cooling
2
Maximum Capacity Btu/h 30,000
Rated Capacity Btu/h 30,000
Minimum Capacity Btu/h 9,000
Maximum Power Input W 3,000
Rated Power Input W 3,000
Moisture Removal Pints/h 8.60
Sensible Heat Factor 0.68
Power Factor % 93.8
Efficiency
SEER 19.1
EER
1
10.0
Electrical
Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz
Guaranteed Voltage Range V AC 198 – 253
Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Voltage: Indoor - Remote controller V DC 12
Recommended Fuse/Breaker Size A 25
Recommended Wire Size (Indoor - Outdoor) AWG 14
Indoor Unit
MCA A 2.73
Fan Motor Full Load Amperage A 2.18
Fan Motor Output W 121
Airflow Rate, Dry CFM 618-742-883
Airflow Rate, Wet CFM 578-702-843
External Static Pressure in.WG 0.14-0.20-0.28-0.40-0.60
Sound Pressure Level dB(A) 30-34-39
Drain Pipe Size In. (mm) 1-1/4 (32)
Condensate Lift Mechanism, Max. Distance In. (mm) 27-9/16 (700)
Heat Exchanger Type Plate fin coil
External Finish Color Galvanized
Unit Dimensions
W: In. (mm) 43-5/16 (1100)
D: In. (mm) 28-7/8 (732)
H: In. (mm) 9-7/8 (250)
Package Dimensions
W: In. 53-3/16
D: In. 34-11/16
H: In. 13-7/16
Unit Weight Lbs. (kg) 69 (31)
Package Weight Lbs. 82
Indoor Unit Operating
Temperature Range
Cooling Intake Air Temp (Maximum / Minimum) °F 90 DB, 73 WB / 66 DB, 59 WB
SPECIFICATIONS: PEAD-A30AA7 & PUY-A30NHA7(-BS)
Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.