Operation Manual
10
3.Operation
■
Manualvaneangle(Wiredremotecontroller)
F1 F2 F3 F4
Main
Main display:
Cursor Page
Main menu
Maintenance
Initial setting
Service
F1 F2 F3 F4
Maintenance menu
Main menu:
Cursor
Auto descending panel
Manual vane angle
3D i-See sensor
F1 F2 F3 F4
Manual vane angle
Input display:
Cur. Address Check
Ref. address
Unit No.
Identify unit Check button
F1 F2 F3 F4
Manual vane angle
Manual vane angle
Select:
Setting
Outlet Angle
Note:
Donotsetthedraftreductioninanenvironmentwithhighhumidity.
Otherwise,condensationmayformanddrip.
1 Select “Maintenance” from the
Main menu (refer to page 8), and
press the [SELECT] button.
2 Select “Manual vane angle” with
the [F1] or [F2] button, and press
the [SELECT] button.
3 Move the cursor to “Ref. address”
or “Unit No.” with the [F1] button to
select.
Select the refrigerant address and
the unit number for the units to
whose vanes are to be xed, with
the [F2] or [F3] button, and press
the [SELECT] button.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to con rm the
unit.
The vane of only the target indoor
unit is pointing downward.
4 The current vane setting will ap-
pear.
Select the desired outlets from 1
through 4 with the [F1] or [F2] but-
ton.
• Outlet: “1”, “2”, “3”, “4” and “1, 2, 3,
4, (all outlets)”
Press the [F3] or [F4] button to go
through the option in the order of
“No setting (reset)”, “Step 1”, “Step
2”, “Step 3”, “Step 4”, “Step 5” and
“Draft reduction*”.
Select the desired setting.
* Draft reduction
The air ow direction for this setting
is more horizontal than the air ow
direction for the “Step 1” setting in
order to reduce a drafty feeling.
The draft reduction can be set for
only 1 vane.
■
Vanesetting
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being trans-
mitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above when the
transmission is completed.
Make the settings for other outlets, following the same procedures.
Ifalloutletsareselected,
willbedisplayedthenexttime
theunitgoesintooperation.
Navigating through the screens
• To go back to the Main menu ................ [MENU] button
• To return to the previous screen .......... [RETURN] button
■ Manualvaneangle(Wirelessremotecontroller)
Fig.1
A
Fig.2
B
Fig.3
Step 1 Step 2
Step 3
No setting
Draft
reduction*
All outlets
Step 5Step 4
1 Going to the Manual vane setting
mode
Press the
button.
(Start this operation from the status
of remote controller display turned
off.)
“FUNCTION” is lit and “1” blinks.
(Fig. 1)
Press the button to select “2”,
and then press the button.
2 Selecting the vane number (Fig. 2)
Press the buttons to select the
vane number A, and then press
the button.
3 Setting the vane angle (Fig. 3)
Press the buttons to select the
vane angle B.
Point the wireless remote controller
toward the receiver on the indoor
unit, and then press the
button.
Display
Setting Step 1 Step 2 Step 3 Step 4
Display
No display
Setting Step 5 No setting Draft reduction*
* The draft reduction can be set for only 1 vane.
The setting is enabled only for the last vane that was set.