Engineering Manual

40
PCA-A24KA7 PCA-A30KA7 PCA-A36KA7 PCA-A42KA7
CN3C
(BU)
1
1
3
4
5 1
4 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
CN2L
(RD)
ON OFF
SWE
J42J41
SW2SW1
LED3 LED2 LED1
LED2
LED1
RU
SW2
SW1
CNB
9
5
TH2 TH5 TH1
MV
BZ
M
W.B
R.B
I.B
1 4
2 1
21
12
21
2
Refer to tables 1 and 2
TRANSMISSION
WIRES
DC12V
TB4
YE
OG
OG
BN
YE
OG
TO OUTDOOR
UNIT
1 3 5
3 1
X1
M
1~
DP (OPTION PART)
(OPTION PART)
CNP
(BU)
FUSE
CN01
(BK)
S1
S2
S3
7 4 1
3~
MF
MS
1
3
CN22
(BU)
CNV
(WH)
Pair No.
CNMF
(WH)
CN20
(RD)
CN44
(WH)
CN32
(WH)
CN51(WH)
CN41(WH)
<Table 1>
SW1(MODEL SELECTION)
Be sure to turn off the source power
and then disconnect fan motor connector CNMF.
(Failure to do so will cause trouble in fan motor)
CN24
(YE)
1
<Table 2>
SW2(CAPACITY CODE)
Manufacture/Service Manufacture/Service
MODELS
SW2
PCA-A36KA
MODELS
ON
OFF
1 2 3 4 5
PCA-A24KA
ON
OFF
1 2 3 4 5
PCA-A42KA
ON
OFF
1 2 3 4 5
PCA-A30KA
ON
OFF
1 2 3 4 5
SW1
ON
OFF
1 2 3 4 5
Manufacture/Service
The black square(■)indicates a switch position.
1
2
TB5
TB6
1
2
SYMBOL SYMBOLNAME NAME
I.B
INDOOR CONTROLLER BOARD
FUSE (T6.3AL250V)
CONNECTOR (LOSSNAY)
CONNECTOR (REMOTE SWITCH)
CONNECTOR (HA TERMINAL-A)
CONNECTOR (CENTRALLY CONTROL)
POWER SUPPLY (I.B)
POWER SUPPLY (R.B)
TRANSMISSION (INDOOR-OUTDOOR)
RELAY (DRAIN PUMP)
SWITCH (MODEL SELECTION)
Refer to <Table 1>.
SWITCH (CAPACITY CODE) Refer to <Table 2>.
CONNECTOR (EMERGENCY OPERATION)
FAN MOTOR
VANE MOTOR
DRAIN PUMP
DRAIN FLOAT SWITCH
TERMINAL BLOCK (
INDOOR/OUTDOOR CONNECTING LINE
)
TERMINAL BLOCK (REMOTE CONTROLLER
TRANSMISSION LINE)
ROOM TEMP. THERMISTOR
(32ºF / 15kΩ, 77ºF / 5.4kΩ DETECT)
PIPE TEMP. THERMISTOR/LIQUID
(32ºF / 15kΩ, 77ºF / 5.4kΩ DETECT)
COND. / EVA. TEMP. THERMISTOR
(32ºF / 15kΩ, 77ºF / 5.4kΩ DETECT)
MF
FUSE
MV
DP
CN2L
CONNECTOR (BACK-UP HEATING)
CN24
FS
CN32
CN41
CN51
TB4
LED1
TB5
LED2
TH1
LED3
X1
TH2
SW1
TH5
SW2
SWE
1.SymboIs used in wiring diagram above are, :Connector, :Terminal block.
2.Indoor and outdoor connecting wires are made with poIarities, make wiring matching terminal numbers (S1, S2, S3).
3.Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring for servicing.
4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of 208V/230V), adopting superimposed
system of power and signal.
For power supply system of this unit, refer to the caution label located near this diagram.
1:Use copper supply wire.
Utilisez des fils d’alimentation en cuivre.
W.B
RU
BZ
LED1
LED2
SW1
SW2
OPTION PARTS
PCB FOR IR WIRELESS REMOTE CONTROLLER
RECEIVING UNIT
BUZZER
LED (OPERATION INDICATION : GREEN)
LED (PREPARATION FOR HEATING : ORANGE)
EMERGENCY OPERATION (HEAT)
EMERGENCY OPERATION (COOL)
Notes:
CN105
CONNECTOR
R.B
WIRED REMOTE CONTROLLER BOARD
MT
I-SEE SENSOR MOTOR
TB6
TERMINAL BLOCK (REMOTE CONTROLLER
TRANSMISSION LINE)
CN4F
(WH)
When attaching
drain pump
(Option part),
remove the
jumper
connector
CN4F and fit
the drain float
switch (FS).
When attaching
drain pump
(Option part)
FS
1 4
1 4 1 6
CN90
(WH)
CN4F
(WH)
CN6Y
(RD)
CN105
(RD)
CN4Y
(WH)
4
5
1 5
1 9
M
I-SEE
SENSOR
I-SEE SENSOR
(OPTION PART)
MT
(OPTION PART)