Catalogue

COOLING CAPACITY
Model
Indoor Air
Outdoor Intake air D.B. Temperature (˚ F)
IWB (˚ F)
75 85 95 105 115
TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC
MUZ-FH06NA
71 7.4 6.1 0.28 6.9 5.7 0.31 6.5 5.3 0.33 6 5 0.35 5.5 4.6 0.36
67 7 6.7 0.26 6.5 6.2 0.29 6 5.8 0.32 5.6 5.4 0.33 5.1 4.9 0.35
63 6.5 7.2 0.25 6.1 6.6 0.28 5.6 6.2 0.3 5.1 5.6 0.32 4.7 5.1 0.33
MUZ-FH09NA-1
71 11 8.7 0.5 10.3 8.1 0.55 9.7 7.6 0.59 9 7.1 0.62 8.3 6.5 0.64
67 10.4 9.6 0.47 9.7 8.9 0.52 9 8.3 0.56 8.4 7.7 0.59 7.7 7.1 0.62
63 9.8 10.3 0.45 9.1 9.6 0.5 8.5 8.9 0.53 7.7 8.1 0.57 7 7.4 0.59
MUZ-FH12NA-1
71 14.7 10.2 0.77 13.7 9.6 0.85 12.9 9 0.91 12 8.4 0.96 11 7.7 1
67 13.9 11.6 0.73 13 10.8 0.8 12 10 0.87 11.2 9.3 0.92 10.3 8.5 0.97
63 13.1 12.6 0.7 12.1 11.7 0.77 11.3 10.9 0.83 10.3 9.9 0.89 9.4 9 0.92
MUZ-FH15NA
71 18.4 10.4 1.07 17.2 9.7 1.17 16.1 9.1 1.26 15 8.5 1.33 13.8 7.8 1.38
67 17.4 12.2 1.01 16.2 11.3 1.11 15 10.5 1.2 14 9.8 1.27 12.8 9 1.33
63 16.4 13.6 0.96 15.2 12.6 1.06 14.1 11.8 1.15 12.8 10.7 1.22 11.7 9.8 1.27
MUZ-FH18NA2
71 21.1 11.3 1.22 19.7 10.6 1.34 18.5 9.9 1.44 17.2 9.2 1.52 15.8 8.5 1.58
67 20 13.4 1.16 18.6 12.4 1.27 17.2 11.5 1.38 16 10.7 1.46 14.7 9.9 1.53
63 18.7 15.1 1.1 17.4 14 1.22 16.2 13 1.31 14.7 11.8 1.4 13.4 10.8 1.46
MSZ AND MUZ-FH COOLING CAPACITY
NOTE: 1. IWB: Intake air wet-bulb temperature
SHC: Sensible Heat Capacity (x103 Btu/h)
TC: Total Capacity (x103 Btu/h)
TPC: Total Power Consumption (kW)
2. SHC is based on 80˚ F of indoor Intake air DB temperature.
56 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS