*Air coverage represents the distance with one ft/sec air speed when blowing out
horizontally from the unit operating at the High fan speed. This is only a general
guideline; actual coverage depends on size and layout of the room.
M-SERIES AIR OUTLET COVERAGE RANGE*
It is very important that all contractors follow proper procedure and size
units based on a Manual J calculation. A load calculation takes into
account all the factors that cause the building to lose heat in the winter
and gain heat in the summer. Some of the factors taken into consideration
are exposed walls, insulation, windows, doors, and even the direction
the building faces.
INVERTER-driven technology has changed the way heat pumps are used.
Because the inverter can vary the capacity of the system, we can now
size units based on the largest load, which in many cases may be the
heat load. When single speed compressors are sized on heat load and
changed over to cooling, the units can be grossly over-sized. The result
is very little dehumidification and comfort problems.
Using charts like the ones below from the technical service manual, you
can check the equipment capacity at the design temperatures for heating
and cooling. If these values fall within both the heating and cooling
capacity ranges of the system, you can select that system
with confidence.
M-SERIES SIZING
Model Refrigerant Piping Length (One Way)
25 Ft (Std) 40 Ft 65 Ft 100 Ft
MUZ-GE09NA2
Capacity x 1.0
Capacity
x 0.954
Capacity
x 0.878
-
MUZ-GE12NA2
MUZ-GE15NA2
MUZ-GE18NA-1
MUZ-GE24NA Capacity x 1.0 Capacity
x 0.954
Capacity
x 0.878
Capacity
x 0.771
MUZ-D30NA-1 Capacity x 1.0 Capacity
x 0.95
Capacity
x 0.878
Capacity
x 0.713
MUZ-D36NA-1
MUY-GE09NA2 Capacity x 1.0 Capacity
x 0.954
Capacity
x 0.878
-
MUY-GE12NA2
MUY-GE15NA2
MUY-GE18NA-1
MUY-GE24NA Capacity x 1.0 Capacity
x 0.954
Capacity
x 0.878
Capacity
x 0.771
MUY-D30NA-1 Capacity x 1.0 Capacity
x 0.95
Capacity
x 0.878
Capacity
x 0.713
MUY-D36NA-1
MUZ-FE09NA-1 Capacity x 1.0 Capacity
x 0.945
Capacity
x 0.878
-
MUZ-FE12NA-1
MUZ-FE18NA
Capacity x 1.0
Capacity
x 0.945
Capacity
x 0.878
Capacity
x 0.771
MUZ-FH09NA
Capacity x 1.0
Capacity
x 0.945
Capacity
x 0.878
-
MUZ-FH12NA
MUZ-FH15NA
Capacity x 1.0
Capacity
x 0.945
Capacity
x 0.878
Capacity
x 0.771
MUZ-FH18NA
SUZ-KA09NA
Capacity x 1.0
Capacity
x 0.954
Capacity
x 0.878
-
SUZ-KA12NA
SUZ-KA15NA
SUZ-KA18NA
Model Mode Function
Airflow
(CFM)
Coverage
(FT)
MSZ/Y-GE06NA-9
MSZ/Y-GE09NA-9
MSZ/Y-GE12NA-9
HEAT DRY 406 29.5
COOL WET 286 21.0
MSZ/Y-GE15NA-9
HEAT DRY 463 33.5
COOL WET 385 28.0
MSZ/Y-GE18NA-9
HEAT DRY 512 36.9
COOL WET 385 28.0
MSZ/Y-GE24NA
HEAT DRY 738 36.9
COOL WET 661 33.2
MSZ/Y-D30NA-8
MSZ/Y-D36NA-8
HEAT DRY 848 45.0
COOL WET 763 40.7
MSZ-FE09NA-8
HEAT DRY 381 27.7
COOL WET 307 22.4
MSZ-FE12NA-8
HEAT DRY 420 30.4
COOL WET 350 25.4
MSZ-FE18NA
HEAT DRY 738 36.9
COOL WET 661 33.2
MSZ-FH09NA
HEAT DRY 437 29.8
COOL WET 328 22.5
MSZ-FH12NA
HEAT DRY 454 31.0
COOL WET 342 23.5
MSZ-FH15NA
HEAT DRY 497 33.8
COOL WET 354 24.1
MSZ-FH18NA
HEAT DRY 514 23.0
COOL WET 376 16.7
MFZ-KA09NA
HEAT DRY 332 15.4
COOL WET 303 14.2
MFZ-K A12NA
HEAT DRY 335 15.6
COOL WET 309 14.5
MFZ-K A18NA
HEAT DRY 434 20.0
COOL WET 379 17.5
SLZ-KA09NA
HEAT DRY 350 12.1
COOL WET 320 1.1
SLZ-KA12NA
HEAT DRY 390 13.5
COOL WET 350 12.1
SLZ-KA15NA HEAT DRY 390 13.5
COOL WET 350 12.1
M-SERIES COOLING CAPACITY CORRECTION FACTOR