Catalogue

ADDITIONAL M-SERIES INFORMATION
AVAILABLE INDOOR UNITS LINE SET SIZE
MSZ Wall-mounted
MSZ-GL06NA-U1 3/8" gas x 1/4" liquid
MSZ-GL09NA-U1 3/8" gas x 1/4" liquid
MSZ-GL12NA-U1 3/8" gas x 1/4" liquid
MSZ-GL15NA-U1 1/2" gas x 1/4" liquid
MSZ-GL18NA-U1 1/2" gas x 1/4" liquid
MSZ-GL24NA-U1 5/8" gas x 3/8" liquid
MSZ-FH06NA 3/8" gas x 1/4" liquid
MSZ-FH09NA 3/8" gas x 1/4" liquid
MSZ-FH12NA 3/8" gas x 1/4" liquid
MSZ-FH15NA 3/8" gas x 1/4" liquid
MSZ-FH18NA2 1/2" gas x 1/4" liquid
MFZ Floor-standing
MFZ-KA09NA 3/8" gas x 1/4" liquid
MFZ-KA12NA 3/8" gas x 1/4" liquid
MFZ-KA18NA 1/2" gas x 1/4" liquid
MVZ Multi-position
MVZ-A12AA4 1/2" gas x 1/4" liquid
MVZ-A18AA4 1/2" gas x 1/4" liquid
MVZ-A24AA4 5/8" gas x 3/8" liquid
MVZ-A30AA4 5/8" gas x 3/8" liquid
MVZ-A36AA4 5/8" gas x 3/8" liquid
PLA Ceiling-recessed
PLA-A12BA6 1/2" gas x 1/4" liquid
PLA-A18BA6 1/2" gas x 1/4" liquid
PLA-A24BA6 5/8" gas x 3/8" liquid
PLA-A30BA6 5/8" gas x 3/8" liquid
PLA-A36BA6 5/8" gas x 3/8" liquid
PCA Ceiling-suspended
PCA-A24KA6 5/8" gas x 3/8" liquid
SLZ Ceiling-recessed
SLZ-KA09NA 3/8" gas x 1/4" liquid
SLZ-KA12NA 3/8" gas x 1/4" liquid
SLZ-KA15NA 1/2" gas x 1/4" liquid
SEZ/PEAD Horizontal-ducted
SEZ-KD09NA4 3/8" gas x 1/4" liquid
SEZ-KD12NA4 3/8" gas x 1/4" liquid
SEZ-KD15NA4 1/2" gas x 1/4" liquid
SEZ-KD18NA4 1/2" gas x 1/4" liquid
PEAD-A24AA5 5/8" gas x 3/8" liquid
PEAD-A30AA5 5/8" gas x 3/8" liquid
PEAD-A36AA5 5/8" gas x 3/8" liquid
PORT ADAPTER GUIDE
Notes for application:
* Check the lineset sizes for your indoor selected models.
* Select the branch box or boxes needed for your
application.
* Compare indoor unit lineset sizes to branch box or outdoor
unit port sizes.
* *Connect 15K + indoor units to the larger 1/2" port on the
PAC-MKA50BC branch box or outdoor unit.
* Adapt lineset size with appropriate port adapter from above
list.
* *When using the PLA-A24BA6, PEAD-A24AA5, PEAD-
A30AA5, PEAD-A36AA5, MSZ-GL24NA two port adapters
will be needed
1-MAC-A456JP-E (1/2" x 5/8") or 1-PAC-SG76RJ-E (3/8" x
5/8") and 1 - PAC-493Pl (1/4" x 3/8").
MAC-A454JP-E 3/8" x 1/2"
MAC-A455JP-E 1/2" x 3/8"
MAC-A456JP-E 1/2" x 5/8"
PAC-SG76RJ-E 3/8" x 5/8"
PAC-493PL 1/4" x 3/8"
PORT ADAPTERS PART NUMBERS
PORT GAS LIQUID
MXZ-2B20NA-1
A; B 3/8" 1/4"
MXZ-3C24NA
A 1/2" 1/4"
B; C 3/8" 1/4"
MXZ-3C30NA
A 1/2" 1/4"
B; C 3/8" 1/4"
MXZ-4C36NA
A 1/2" 1/4"
B; C; D 3/8" 1/4"
MXZ-5C42NA
A 1/2" 1/4"
B; C; D; E 3/8" 1/4"
MXZ-2C20NAHZ
A; B 3/8" 1/4"
MXZ-3C24NAHZ
A 1/2" 1/4"
B; C 3/8" 1/4"
MXZ-3C30NAHZ
A 1/2" 1/4"
B; C 3/8" 1/4"
THE FOLLOWING MXZ UNITS
MUST UTILIZE AT LEAST ONE
BRANCH BOX
MXZ-8C48NA
MXZ-4C36NAHZ
MXZ-5C42NAHZ
MXZ-8C48NAHZ
BRANCH BOXES
PORT GAS LIQUID
PAC-MKA30BC [3-Port]
A; B; C 3/8" 1/4"
PAC-MKA50BC [5-Port]
A; B; C; D 3/8" 1/4"
E 1/2" 1/4'
M-SERIES OPERATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
MODELS CONDITIONS
Cooling
Maximum
SUZ
95° F D.B., 71° F W.B.
MXZ-2B20NA-1
MXZ-3C24/3C30/4C36/5C42NA
MXZ-2C20/3C24/3C30NAHZ
MUZ/Y-GL/D
90° F D.B., 73° F W.B.
MUZ-FH
MXZ-8C48NA
MXZ-4C36/54C42/8C48NAHZ
Minimum
MUZ/Y-GL/D
67° F D.B., 57° F W.B.
MUZ-FH
MXZ-2B20NA-1
MXZ-3C24/3C30/4C36/5C42NA
MXZ-2C20/3C24/3C30NAHZ
MXZ-8C48NA
MXZ-4C36/54C42/8C48NAHZ
52 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS