Engineering Manual
Table Of Contents
5
OCD699
SUZ-KA09NA(H)2.MX SUZ-KA12NA(H)2.MX (MLZ Combination)
Model name
Indoor unit
MLZ-KP09NA MLZ-KP12NA
Outdoor unit
SUZ-KA09NA(H)2 SUZ-KA12NA(H)2
Cooling
Rated Capacity Btu/h 9000 12000
Capacity Range Btu/h 3600-9000 3900-12000
Total input W 710 960
Energy Efciency
EER 12.6 12.5
SEER 19.5 19.8
Moisture Removal Pints/h 1.5 2.8
Sensible Heat Factor 0.82 0.74
Heating at 47°F
Rated Capacity Btu/h 12000 15400
Capacity Range Btu/h 4010-13000 4600-17000
Total input W 860 1300
HSPF(Region IV) Btu/h/W 13.3(12.5) 12.1(11.6)
Heating at 17°F
Rated Capacity Btu/h 7700 9900
Rated Total input W 700(830) 1020(1150)
Maximum Capacity Btu/h 7700 9900
Maximum Total Input W 700(830) 1020(1150)
Power supply
Voltage, Phase, Cycle 208/230V, 1-phase, 60Hz
Voltage
Indoor - Outdoor S1-S2 AC 208/230V
Indoor - Outdoor S2-S3 DC12-24V
Indoor - Remote controller DC12V
Indoor unit
MCA A 1.0
Fan Motor F.L.A 0.68
Fan Motor Output W 30
Air ow (SLo-Lo-Mid-Hi)
Cooling DRY(CMM) 212-254-283-311 212-258-297-332
Heating WET(CMM) 180-216-240-264 180-219-252-282
Heating (CFM) 212-247-290-325 212-272-311-350
External Static Pressure in WG 0
Sound Pressure Level
(Lo-Mid-Hi)
Cooling dB (A) 27-31-34-38 27-32-36-40
Heating dB (A)
26-29-34-37 26-32-36-40
External Finish Color
Munsell 4.0GY 9.1/0.2
Dimensions
W: in 43-3/8
D: in 14-3/16
H: in 7-5/16
Weight Unit lbs 34
Field Drainpipe O.D. in O.D. 1-1/4
Refrigerant pipe Gas in 3/8
Refrigerant pipe Liquid
in 1/4
Outdoor unit
MCA A 9
MOCP A 15 16
Fan Motor F.L.A. 0.50
Compressor
Model(Type) DC INVERTER-driven DC INVERTER-driven Twin Rotary
R.L.A. 6.2 6.6
L.R.A. 7.7 8.2
Air ow (Cooling/Heating) CFM (1,229/1,172) (1,229/1,172)
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
SPL (Cooling) dB (A) 48 49
SPL (Heating) dB (A) 50 51
External Finish Color Munsell No.3Y 7.8/1.1
Dimension
W: in 31-1/2
D:in 11-1/4
H: in 21-5/8
Weight
lbs
81
Remote Controller
Type Wireless Remote Controller
Refrigerant
Type R410A
Charge lbs, oz 2,5 2,9
Oil Type(Fl.oz.) FV50S(9.1) FV50S(11.8)
Refrigerant Pipe
Gas side O.D. in 3/8
Liquid side O.D. in 1/4
Height Difference (Max) ft 40
Length (Max.) ft 65
Connection Method
Indoor/Outdoor Flared/Flared
Operation Guarantee
Cooling
°F
14 - 115
Heating
°F
-4 - 75
NOTES : *1.Rating conditions (cooling)-Indoor : D.B. 26.7°C(80°F), W.B. 19.4°C(67°F) Outdoor : D.B. 35°C(95°F), W.B. 23.9°C(75°F)
(heating)-Indoor : D.B. 21.1°C(70°F), W.B. 15.6°C(60°F) Outdoor : D.B. 8.3°C(47°F), W.B. 6.1°C(43°F)
*2.Rating conditions(heating)-Indoor : D.B. 21.1°C(70°F), W.B. 15.6°C(60°F) Outdoor : D.B. -8.3°C(17°F), W.B. -9.4°C(15°F)
Operating range
Indoor intake air temperature
D.B. 35°C(95°F), W.B. 21.7°C(71°F)
D.B. 19.4°C(67°F), W.B. 13.9°C(57°F)
D.B. 26.7°C(80°F), W.B. 19.4°C(67°F)
D.B. 21.1°C(70°F), W.B. 15.6°C(60°F)
Outdoor intake air temperature
D.B. 46°C(115°F)
D.B. -10°C(14°F)
D.B. 24°C(75°F), W.B. 18°C(65°F)
D.B. -20°C(-4°F), W.B. -21°C(-5°F)
Cooling
Heating
Maximum
Minimum
Maximum
Minimum