Specifications
19
Having trouble? Here is the solution. (Unit is operating normally.)
Noise is louder than specifications.
Nothing appears in the wireless remote controller display, the display is
faint, or signals are not received by the indoor unit unless the remote con-
troller is close.
The operation lamp near the receiver for the wireless remote controller on
the indoor unit is flashing.
■ The indoor operation sound level is affected by the acoustics of the par-
ticular room as shown in the following table and will be higher than the
noise specification, which was measured in an echo-free room.
■ The batteries are low.
Replace the batteries and press the Reset button.
■ If nothing appears even after the batteries are replaced, make sure that
the batteries are installed in the correct directions (+, –).
■ The self diagnosis function has operated to protect the air conditioner.
■ Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name.
High sound-
absorbing rooms
Broadcasting
studio, music
room, etc.
3 to 7 dB
Normal rooms
Reception room,
hotel lobby, etc.
6 to 10 dB
Low sound-
absorbing rooms
Office, hotel
room
9 to 13 dB
Location
examples
Noise levels
11. Trouble Shooting
12. Specifications
Model
Power source (voltage <V>/Frequency <Hz>)
Rated Input (Indoor only) <kW>
Rated Current (Indoor only) <A>
HEATER <kW>
Dimension (Height) <mm>
Dimension (Width) <mm>
Dimension (Depth) <mm>
Fan airflow rate (Low-Middle2-Middle1-High)
<m
3
/min>
Noise level (Low-Middle2-Middle1-High) <dB>
Net weight <kg>
PLA-RP35AA PLA-RP50AA PLA-RP60AA PLA-RP71AA
PLA-RP100AA2
PLA-RP125AA2 PLA-RP140AA2
~/N 230/50
0.16/0.16 0.16/0.16 0.16/0.16 0.16/0.16 0.18/0.18 0.18/0.18 0.18/0.18
0.79/0.79 0.79/0.79 0.79/0.79 0.79/0.79 0.92/0.92 0.92/0.92 0.92/0.92
– – – – – – –
258(30) 298(30)
840(950)
840(950)
11-12-13-14 14-15-16-18 15-16-18-20 19-21-23-27 24-25-27-30
27-28-29-31 28-29-31-33 28-30-32-34 33-36-39-41 37-40-43-45
24(5) 32(5)
*1 The figure in () indicates GRILL’s.
Model
Power source (voltage <V>/Frequency <Hz>)
Rated Input (Indoor only) <kW>
Rated Current (Indoor only) <A>
HEATER <kW>
Dimension (Height) <mm>
Dimension (Width) <mm>
Dimension (Depth) <mm>
Fan airflow rate (Low-Middle2-Middle1-High)
<m
3
/min>
Noise level (Low-Middle2-Middle1-High) <dB>
Net weight <kg>
PLH-P35AAH PLH-P50AAH PLH-P60AAH PLH-P71AAH PLH-P100AAH PLH-P125AAH PLH-P140AAH
~/N 230/50
0.16/0.16 0.16/0.16 0.16/0.16 0.16/0.16 0.25/0.25 0.33/0.33 0.33/0.33
0.79/0.79 0.79/0.79 0.79/0.79 0.79/0.79 1.25/1.25 1.64/1.64 1.64/1.64
1.29 1.29 1.93 1.93 2.39 2.76 2.76
258(30) 298(30)
840(950)
840(950)
11-12-13-14 14-15-16-18 15-16-18-20 20-23-26-28 22-25-28-30
27-28-29-31 28-29-31-33 28-30-32-34 33-36-39-41 37-40-43-45
26(5) 32(5) 34(5)
*1 The figure in () indicates GRILL’s.
Model
Power source (voltage <V>/Frequency <Hz>)
Rated Input (Indoor only) <kW>
Rated Current (Indoor only) <A>
HEATER <kW>
Dimension (Height) <mm>
Dimension (Width) <mm>
Dimension (Depth) <mm>
Fan airflow rate (Low-Middle2-Middle1-High or
Low-High) <m
3
/min>
Noise level (Low-Middle2-Middle1-High or
Low-High) <dB>
Net weight <kg>
PKA-RP35GAL PKA-RP50GAL PKA-RP60FAL PKA-RP71FAL
PKA-RP100FAL
~/N 230/50
0.07/0.07 0.07/0.07 0.09/0.09 0.09/0.09 0.11/0.11
0.33/0.33 0.33/0.33 0.43/0.43 0.43/0.43 0.52/0.52
– – – – –
340
990 1400 1680
235
9-10-11-12 15-20 22-28
36-38-41-43 39-45 41-46
16 24 28