Specifications
93
Other function selections
Now that you know how to change the power voltage setting, there are several other settings that can be changed as well. The following Table
lists the various settings that can be changed through the remote controller and the default settings of the various units.
Things to remember when entering function selections:
The basic procedure for entering function selections is the same as described for switching between power voltages. However, there are
some differences at step
33
for selecting the unit number, step
55
for selecting the mode number and step
66
for selecting the unit number.
The following Tables 2 and 3 list the various function settings, mode numbers and setting numbers. Table 2 details the functions of the
entire refrigerant system while Table 3 shows the functions that can be set for the indoor unit.
In case of setting the mode number from 15 to 28 with the wired remote controller, shift to the function selecting mode by pressing
JJ
(Air
direction) button and
BB
(TEST RUN) button at the same time for 2 seconds or more.
(The function selecting mode will be released in the same way as the one of setting it.)
Function
Mode
No.
01
02
03
04
15
16
17
19
07
08
09
10
11
12
13
23
24
25
27
28
Settings
PLH-P·KAH
PLA-P·KA
PCH-P·GAH
PCA-P·GA
PKH-P·GALH
PKA-P·GAL
Power failure
automatic recovery
Indoor temperature
detecting
LOSSNAY
connectivity
Power voltage
Frost prevention
temperature
Humidifier control
Change of
defrosting control
Thermo differential
setting
Filter sign
Fan speed
No. of air outlets
Installed options (high-
performance filter)
Up/down vane
setting
Energy saving air flow
(Heating mode)
Humidifier
(Direct Add-on type)
Swing
Set temperature in heating
mode 4deg-up
Fan speed when the
heating thermostat is
OFF.
Fan speed when the
cooling thermostat is OFF.
Detection of abnormality
Not available
Available
Indoor unit operating average
Set by indoor unit's remote controller
Remote controller's internal sensor
Not supported
Supported (indoor unit in not equipped with outdoor-air intake)
Supported (indoor unit in equipped with outdoor-air intake)
240V
220V, 230V
2:
3:
When the compressor operates, the humidifier also operates.
When the fan operates, the humidifier also operates.
Standard
High humidity region
Normal
5:
10:
100Hr
2500Hr
No filter sign indicator
Quiet
Standard
High ceiling
4 directions
3 directions
2 directions
Not supported
Supported
No vanes
Equipped with vanes (No.1 set)
Equipped with vanes (No.2 set)
Disabled
Enabled
Not supported
supported
Not available
Available
Available
Not available
Extra low
Low
Setting fan speed
Setting fan speed
Stop
Available
Not available
PMH-P·BA PCA-P·HA
PLH-P·KAH.UK
PLA-P·KA.UK
PEHD-P·EAH
PEAD-P·EA
PLH-P·AAH
PLA-P·AA
PKH-P·FAH
PKA-P·FAL
PSH-P·GAH
PSA-P·GA
standard
High ceiling 1
High ceiling 2
PLH-P·AAH/PLA-P·AA type
Table 1
5 To select multiple functions continuously
Repeat steps 3 and 4 to change multiple function settings continuously.
6 Complete function selection
Direct the wireless remote controller toward the sensor of the indoor unit and
press the button E.
Note:
Whenever changes are made to the function settings after construction or
maintenance, be sure to record the added functions with an “ ”, in the
“Check” column provided on the chart.
OCT03-E-4.qxp 04.3.26 1:52 PM Page 93