Specifications
19
9
W.B
GRY
5
6
88H
26H
1
6
2
HEATER
CN24
(YLW)
1
WHT
WHT
YLW
YLW
1
2
REMOTE
CONTROLLER
CN22 (BLU)
2
1
VANE
POSITION
CN23 (GRN)
FS2
FS1
5
TB2
88H
N
PE
L
POWER SUPPLY
~/N(1PHASE)
220V-240V 50Hz
BLU
RED
3
WHT
RED
RED
1
2
H1
GRN/YLW
1
2
3
CONTROLLER BOARD
CN02 (WHT)
R.B
OUTDOOR UNIT
CN01 (BLU)
3
1
2
D.U.M
CNP
(BLU)
D.SENSOR
CN31
(WHT)
X4
X3
X1
X4
REMOTE
CONTROLLER
RU
FAN
(WHT)
CN90
(WHT)
WIRELESS
W.R
CNB
SW1
SW2
LED1
BZ
J15
BLK
BLK
BLK
BLK
BLK
BLK
BRN
YLW
ORN
WHT
BLK
BRN
ORN
YLW
BLU
BLU
RED
RED
YLW
YLW
BLK
WHT
RED
PIPE
CN29
(BLK)
2
1
1
2
TH5
GRILLE
4
8
9
6
1
10
5
3
7
2
S1
S3
S2
TB1
L3
PE
L1
L2
N
S1
PE
S3
S2
TB1
L
N
X1
C
MF
3
1
2
5
3
OUTDOOR UNIT
S1
S2
S3
TB4
P. B
ZNR
2
1
F1
2
CN2
1
TB6
LS
H2
MV
DC14V
1
2
TB5
2
1
CN2S(WHT)
CN32
CN2L
1
2
POWER
CN2D (WHT)
LIQUID
CN21
(WHT)
2
1
INTAKE
CN20
(RED)
2
1
1
2
3
SW2
J22
J23
J24
VANE
CNV
(GRN)
X3
SW1
J11
J12
J13
3
1
3
1
J14
3
1
LED1
LED2
1
D.HEATER
CNC
(RED)
LED3
CN41
3
5
POWER
CN03
(RED)
DP
1
FC
I.B
SWE
ON
OFF
J21
TH2
2
DS
3
1
1
TH1
CN25
TRANSMISSION WIRES DC12V
PUH-P1.6, 2, 2.5YGA
(1)
PU(H)-P1.6, 2, 2.5YGAA.UK
POWER SUPPLY
3N~(3PHASE 4WIRES)
380-415V 50Hz
PU(H)-P1.6, 2, 2.5VGA
(1)
PU(H)-P1.6, 2, 2.5VGAA.UK
POWER SUPPLY
~/N(1PHASE)
220-240V 50Hz
BLU
BLU
BRN
BRN
SW1
SW2
Manufacture
service boardMODELS
OFF
ON
432
J14J13J12J11
Service board
Manufacture
MODELS
15
J15
J23J24
1234
ON
OFF
1234
ON
OFF
J23J24
J22J21
J21J22
PLH-P1.6KAH.UK
PLH-P1.6KAH
1
.UK
PLH-P2KAH.UK
PLH-P2KAH1.UK
PLH-P2.5KAH.UK
PLH-P2.5KAH
1
.UK
PLH-P1.6KAH.UK
PLH-P1.6KAH
1
.UK
PLH-P2KAH.UK
PLH-P2KAH1.UK
PLH-P2.5KAH.UK
PLH-P2.5KAH
1
.UK
1234
ON
OFF
J23J24J21J22
Please set the voltage using the
remote controller. For the setting
method, please refer to the indoor
unit Installation Manual.
1. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
3. Make sure that the main power supply of the booster heater is independent.
4. Symbols used in wiring diagram above are,
2. Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers(S1,S2,S3).
:Connector, :Terminal block.
NOTES:
NAME
NAME
SYMBOL
INDOOR CONTROLLER BOARD
NAME
SYMBOL
INDOOR POWER BOARD
VARISTOR
FUSE (4A)
[LEGEND]
F1
REMOTE CONTROLLER BOARD
CONNECTOR (PROGRAM TIMER)
R.B
CN2
ZNR
P. B
CONNECTOR (REMOTE SWITCH)
CONNECTOR (LOSSNAY)
CN2L
CN32
CN41
CONNECTOR (HA TERMINAL-A)
LED1
LED2
POWER SUPPLY (R.B)
LED3
TRANSMISSION (INDOOR-OUTDOOR)
JUMPER WIRE (MODEL SELECTION)
SW1
JUMPER WIRE (CAPACITY CODE)
SW2
SWITCH (EMERGENCY OPERATION)
SWE
I.B
POWER SUPPLY (I.B)
CONNECTOR (HUMIDIFIER)
CN25
FC
FAN PHASE CONTROL
X1
RELAY (DRAIN PUMP/D.HEATER)
X3
RELAY (VANE MOTOR)
X4
RELAY (FAN MOTOR)
TERMINAL BLOCK
TB6
(REMOTE CONTROLLER TRAMSMISSION LINE)
W.B
BZ
RU
BOARD (OPTION)
RECEIVING UNIT
BUZZER
SW1
LED1
SWITCH (HEATING ON/OFF)
LED (RUN INDICATOR)
SW2
SWITCH (COOLING ON/OFF)
WIRELESS REMOTE CONTROLLER
W.R
WIRELESS REMOTE CONTROLLER
(OPTION)
SYMBOL
DRAIN-UP MACHINE
DRAIN SENSOR
DEW PREVENTION HEATER
CAPACITOR (FAN MOTOR)
DP
H2
C
DS
ROOM TEMPERATURE THERMISTOR
TERMINAL BLOCK
FAN MOTOR
TERMINAL BLOCK
(REMOTE CONTROLLER TRANSMISSION LINE)
LIMIT SWITCH
VANE MOTOR
(0;/15K', 25;/5.4K' DETECT)
TERMINAL BLOCK (HEATER)
(INDOOR/OUTDOOR CONNECTING LINE)
LS
MF
TB2
MV
TB5
TB4
TH1
HEATER CONTACTOR
HEATER THERMAL SWITCH
HEATER
THERMAL FUSE (98;,10A), (77;,10A)
CONDENSER/EVAPORATOR TEMPERATURE
THERMISTOR (0;/15K', 25;/5.4K' DETECT)
PIPE TEMPERATURE THERMISTOR/LIQUID
(0;/15K', 25;/5.4K' DETECT)
88H
26H
H1
FS1,2
HEATER
TH2
TH5
PLH-P1.6KAH.UK PLH-P2KAH.UK PLH-P2.5KAH.UK
PLH-P1.6KAH1.UK PLH-P2KAH1.UK PLH-P2.5KAH1.UK
OCT03-E-1.qxp 04.3.26 1:38 PM Page 19