Specifications

128
13-1-2. Indoor controller board
PLH-P•KAH, PLA-P•KA
PLH-P•AAH, PLA-P•AA
PCH-P•GAH, PCA-P•GA
PKH-P•FALH, PKA-P•FAL
PKH-P•GALH, PKA-P•GAL
CN6V
Vane motor output
(MV)
CN32
Connector
(Remote switch)
CN90
Connect to the wireless
remote controller board
(CNB)
CN2D
Connect to the indoor
power board (CN2S)
(12~16V DC)
CN22
Connect to the terminal block(TB5)
(Remote controller connecting wire)
(10~16V DC)
CN21
Pipe temperature
thermistor/Liquid (TH2)
CN20
Room temperature
thermistor (TH1)
CN2L
Connector (LOSSNAY)
CN41
Connector (HA terminal-A)
CN31
Drain sensor (DS)
CN29
Condenser/evaporator
temperature thermistor (TH5)
CN25
Humidifier output
(12~16V DC)
Jumper wire J11~J15
Model setting
Jumper wire J21~J24
Capacity setting
SWE
Emergency operation
LED1
Power supply (I.B)
LED2
Power supply (R.B)
LED3
Transmission
(Indoor/outdoor)
CN03
Connect to the indoor
power board (CN02)
Between 1 to 3 220~240V AC
Between 3 to 5 0~24V DC
(Indoor/outdoor transmission)
CNC
Dew prevention heater (H2)
Between 1 to 3 220~240V AC
CNP
Drain-up machine output (DP)
Between 1 to 3 220~240V AC
FAN
Fan motor output (MF)
Between 1 to 5 220~240V AC
+
}
}
+
}
+
}
+
CNV
Vane moter output (MV)
Between 1 to 3 220~240V AC
OCT03-E-5.qxp 04.3.26 1:53 PM Page 128