3. ELECTRICAL DATA
Rating Conditions (JIS B8616)
Cooling : Indoor 27:DB. 19:WB. Outdoor 35:DB.
Heating : Indoor 20:DB. Outdoor 7:DB. 6:WB.
Indoor
……
220V 50Hz 1phase
Outdoor
…
220V 50Hz 1phase / 380V 50Hz 3phase
IndoorOutdoor
Input (kW)
Current (A)
Starting current (A)
Input (kW)
Current (A)
Starting current (A)
Mode
Capacity (W)
Total Input (kW)
Service Ref.
Cooling
5,300
2.20
0.08
0.38
1.10
2.12
9.83
43
Heating
6,100
2.22
0.08
0.38
1.10
2.14
9.93
43
PCH-2GKA-E
Cooling
6,900
2.52
0.11
0.51
1.17
2.41
11.18
52
Heating
7,000
2.27
0.11
0.51
1.17
2.16
10.02
52
PCH-2.5GKA-E
Cooling
7,400
3.24
0.11
0.51
1.17
3.13
14.67/5.23
54 / 34
Heating
8,400
3.03
0.11
0.51
1.17
2.92
13.68/4.88
54 / 34
PCH-3GKA-E
Cooling
9,900
3.31
0.14
0.68
1.36
3.17
5.29
37
Heating
10,350
3.30
0.14
0.68
1.36
3.16
5.28
37
PCH-4GKSA-E
Cooling
12,200
4.39
0.20
0.96
2.0
4.19
7.32
60
Heating
13,700
4.33
0.20
0.96
2.0
4.13
7.21
60
PCH-5GKSA-E
Cooling
14,400
4.84
0.20
0.96
2.0
4.64
8.10
68
Heating
14,800
4.76
0.20
0.96
2.0
4.56
7.96
68
PCH-6GKSA-E
IndoorOutdoor
Input (kW)
Current (A)
Starting current (A)
Input (kW)
Current (A)
Starting current (A)
Mode
Capacity (W)
Total Input (kW)
Service Ref.
Cooling
5,350
2.25
0.09
0.41
1.15
2.16
9.78
44
Heating
6,150
2.27
0.09
0.41
1.15
2.18
9.87
44
PCH-2GKA-E
Cooling
6,950
2.56
0.12
0.53
1.22
2.44
10.94
52
Heating
7050
2.32
0.12
0.53
1.22
2.20
9.86
52
PCH-2.5GKA-E
Cooling
7,450
3.26
0.12
0.53
1.22
3.14
14.22 / 5.21
56 / 36
Heating
8,450
3.05
0.12
0.53
1.22
2.93
13.27 /4.86
56 / 36
PCH-3GKA-E
Cooling
9,950
3.34
0.15
0.69
1.42
3.19
5.23
39
Heating
10,400
3.33
0.15
0.69
1.42
3.18
5.22
39
PCH-4GKSA-E
Cooling
12,300
4.42
0.22
1.01
2.10
4.20
7.05
63
Heating
13,800
4.37
0.22
1.01
2.10
4.15
6.97
63
PCH-5GKSA-E
Cooling
14,450
4.91
0.22
1.01
2.10
4.69
7.87
71
Heating
14,900
4.79
0.22
1.01
2.10
4.57
7.67
71
PCH-6GKSA-E
IndoorOutdoor
Input (kW)
Current (A)
Starting current (A)
Input (kW)
Current (A)
Starting current (A)
Mode
Capacity (W)
Total Input (kW)
Service Ref.
Cooling
5,400
2.30
0.10
0.43
1.20
2.20
9.86
45
Heating
6,200
2.32
0.10
0.43
1.20
2.22
9.95
45
PCH-2GKA-E
Cooling
7,000
2.59
0.13
0.55
1.27
2.46
10.68
52
Heating
7,100
2.36
0.13
0.55
1.27
2.23
9.78
52
PCH-2.5GKA-E
Cooling
7,500
3.28
0.13
0.55
1.27
3.15
13.82 / 5.16
58 / 37
Heating
8,500
3.07
0.13
0.55
1.27
2.94
12.89 / 4.81
58 / 37
PCH-3GKA-E
Cooling
10,000
3.36
0.16
0.70
1.48
3.20
5.24
40
Heating
10,450
3.35
0.16
0.70
1.48
3.19
5.22
40
PCH-4GKSA-E
Cooling
12,400
4.45
0.24
1.06
2.20
4.21
6.89
65
Heating
13,900
4.40
0.24
1.06
2.20
4.16
6.81
65
PCH-5GKSA-E
Cooling
14,500
4.97
0.24
1.06
2.20
4.73
7.74
74
Heating
15,000
4.82
0.24
1.06
2.20
4.58
7.50
74
PCH-6GKSA-E
Rating Conditions (JIS B8616)
Cooling : Indoor 27:DB. 19:WB. Outdoor 35:DB.
Heating : Indoor 20:DB. Outdoor 7:DB. 6:WB.
Indoor
……
230V 50Hz 1phase
Outdoor
…
230V 50Hz 1phase / 400V 50Hz 3phase
Rating Conditions (JIS B8616)
Cooling : Indoor 27:DB. 19:WB. Outdoor 35:DB.
Heating : Indoor 20:DB. Outdoor 7:DB. 6:WB.
Indoor
……
240V 50Hz 1phase
Outdoor
…
240V 50Hz 1phase / 415V 50Hz 3phase
Refrigerant piping length : 5m
Refrigerant piping length : 5m
Refrigerant piping length : 5m