Unit installation

61
1-3 Wired Remote Controller or Wireless Remote Controller Receiver Built into Indoor Unit
[Floor type (wired remote controller)/4-way ceiling cassette type, ceiling suspended type, wall mounted type (wireless remote
controller)]
Slim Air Conditioner System
Standard 1:1 Simultaneous Twin Simultaneous Triple Simultaneous Quad
[Reference]
For systems containing built-in wired remote controllers (or built-in wireless receiver adapters) and consisting of simultaneous twin, triple and quad
units only, the installed remote controllers (or receiver adapters) must be connected without changing any settings. If the system consists of
different models, keep only one of the remote controllers built into the indoor units, or remove all the remote controller cables and connect them
to other models according to 1-1 or 1-2.
Use the wired remote controllers without setting them as the main and sub controllers.
System diagram
(Wired remote
controller or wireless
remotecontroller
receiver)
Outdoor unit
OC
Indoorunit IC
Wired remote
controller or
reciever R
OC
3(2)
IC
R
Indoor/outdoor
connection cable
OC
3(2)
3(2)
IC-1
IC-2
R-1
R-2
OC
3(2)
3(2)
IC-1
IC-2 IC-3
R-1
R-2 R-3
3(2)
OC
3(2)
3(2)
IC-1
IC-2 IC-3 IC-4
R-1
R-2 R-3 R-4
3(2) 3(2)
* Numbers given in ( ) apply when power is supplied to the indoor and outdoor units separately.
2. 2-remote Controller Operation
2-1 2 Wired Remote Controllers
(R: Wired remote controller)
Slim Air Conditioner System
Standard 1:1 Simultaneous Twin
[Reference]
System
diagram
(Wired
remote
controller)
Outdoor unit OC
Indoor unit IC
Wired remote
controller R
Outdoor unit OC
Indoor unit IC
Wired remote
controller R
Slim Air Conditioner System
Simultaneous Triple Simultaneous Quad
Outdoor unit OC
Indoor unit IC
Wired remote
controller R
Outdoor unit OC
Indoor unit IC
Wired remote
controller R
OC
3(2)
2
IC
R-1
R-2
2
Remote
controller
cable
Indoor/outdoor
connection cable
OC
3(2)
3(2)
2
IC-1
IC-2
R-1
R-2
2
2
OC
2
IC
R-1
R-2
3(2)
OC
3(2)
2
IC-1
IC-2
R-1
R-2
2
3(2)
* Numbers given in ( ) apply when power is supplied to the indoor and outdoor units separately.
If simultaneous twin or triple or quad, connect the remote controller to any one of the indoor units. All functions of the indoor unit can be
controlled even if different models (different types) are mixed.
Do not use crossover wiring among indoor units with simultaneous twin, triple, quad units. (Prohibited item.)
Set one of the remote controllers as the main controller (initial setting) and the other as the sub controller using the remote controller's function
selection.
OC
3(2)
3(2)
2
IC-1
IC-2 IC-3
R-1
3(2)
R-2
2
OC
3(2)
3(2)
2
IC-1
IC-2 IC-3 IC-4
R-1
3(2) 3(2)
R-2
2
OC
3(2)
2
IC-1
IC-2 IC-3
R-1
3(2)
R-2
2
3(2)
OC
3(2)
2
IC-1
IC-2 IC-3 IC-4
R-1
3(2)
R-2
2
3(2)
3(2)
System
diagram
(Wired