Modules are built with countermeasures in case of external load short-circuits to protect against over-current and over-
heating.
Output module specifications
[ Contact output module ]
Item LY10R2
Number of output points 16 points
Rated switching voltage, current
24VDC 2A (resistive load)/point, 8A/common
240VAC 2A (COSf=1)/point, 8A/common
Minimum switching load 5VDC 1mA
Maximum switching load 264VAC 125VDC
Response time
OFF to ON 10ms or less
ON to OFF 12ms or less
Life
Mechanical 20 million times or more
Electrical
Usage environment Switching life
Rated switching voltage/current, rated load 100 thousand times
200VAC 1.5A, 240VAC 1A (COSf = 0.7) 100 thousand times
200VAC 0.4A, 240VAC 0.3A (COSf = 0.7) 300 thousand times
200VAC 1A, 240VAC 0.5A (COSf = 0.35) 100 thousand times
200VAC 0.3A, 240VAC 0.15A (COSf = 0.35) 300 thousand times
24VDC 1A, 100VDC 0.1A (L/R = 7ms) 100 thousand times
24VDC 0.3A, 100VDC 0.03A (L/R = 7ms) 300 thousand times
Maximum switching frequency 3600 times/hour
Surge suppressor
Fuse
Common terminal arrangement 16 points/common
Maximum number of modules specification Counts as 1 module
Number of occupied I/O points 16 points (I/O assignment: 16 input points)
External connections 18-point terminal block
5VDC internal current consumption 460mA (TYP. all points ON)
Weight 0.21kg
[ Triac output module ]
Item LY20S6
NEW
Number of output points 16 points点
Rated load voltage, frequency 100 to 240VAC (+10%/-15%), 50/60Hz(±3Hz)
Maximum load current 0.6A/point, 4.8A/common
Load voltage distortion ratio Within 5%
Maximum load voltage 264VAC
Minimum load voltage/current 24VAC/100mA, 100VAC/25mA, 240VAC/25mA
Maximum inrush current 20A/cycle or less
Leakage current at OFF 3mA or lower (at 240V, 60Hz), 1.5mA or lower (at 120V, 60Hz)
Maximum voltage drop at ON 1.5V or lower (at load current of 0.6A)
Response time
OFF to ON Total of 1ms and 0.5 cycles or less
ON to OFF Total of 1ms and 0.5 cycles or less (rated load, resistive load)
Surge suppressor CR absorber
Fuse None (Attaching a fuse to each external wiring is recommended.)
Common terminal arrangement 16 points/common
Maximum number of modules specification Counts as 1 module
Number of occupied I/O points 16 points (I/O assignment: output 16 points)
External connections 18-point terminal block
5VDC internal current consumption 300mA (TYP. all points ON)
Weight 0.22kg