Programmable Controllers MELSEC-L series Little on size, Large on performance The new L series has a small footprint and is loaded with features.
Simple Convenience that fits in the palm of your hand. The L series is the latest in a long line of MELSEC products renowned for exceptional performance and rock solid reliability. Get the performance, functions, and capabilities required for today's most demanding applications in an incredibly small package. MELSEC-L series greatly expands the range of functionality traditionally associated with compact PLCs and through user-centric design, pushes the limits of ease of use.
Built-in I/O Features P.5 Positioning High-speed Counter Interrupt Input General Purpose I/O Pulse Catch Every L series CPU module comes with 24 points of built-in I/O that support advanced features to meet challenges head on. Built-in Connectivity Ethernet P.7 USB SD Memory Card CC-Link Ver.2.0*2 Convenient communication options and memory card storage are included with every CPU. CPU Features*2 P.
Compact Design Integrated backplane P.9 Mount on standard DIN rail For extension system By eliminating the need for a separate backplane base unit, system design flexibility has been improved and overall size has been reduced. Simple Motion Modules P.47 Positioning Speed Control Torque Control 16-Axis Interpolation Synchronous Control Auto cam generation function Control sophisticated motion applications with ease using proven and innovative features. Analog Modules P.
INDEX L series Features P.5 Flexible CPU P.25 The L series has the ability to flex to meet your application's requirements. MELSEC L series has been designed with three key concepts in mind. The first key is reliability. I/O P.33 Mitsubishi Electric products are world renowned for quality. The second is ease of use. We are committed enabling engineers and programmers to do their job as efficiently as possible to reduce costs. The third key is flexibility. Analog / Temperature Control P.
L series Features L series Built-in I/O Features Every L series CPU comes with 24 points of built-in I/O standard. These I/O points are capable of many functions usually reserved for separate modules. Save on system costs by using the built-in functions rather than relying exclusively on additional modules. The built-in I/O*1 comes in sink or source type format and may be chosen based on the application.
OFF ON at work passing end at work passing start Sensor (Pulse generator) Sensor on time (the time it takes for the work object to pass) A(ON) CPU Using pulse measurement mode, where the input signal ON/ OFF time is 200μs or greater, highly accurate measurements in units of 5μs or greater are possible. For example it is possible to calculate length by knowing the "work object passing speed" and measuring the ON time of the sensor.
L series Features USB port (Mini-B type) Convenient communication and storage options come standard Ethernet port Program, configure, and perform diagnostics on L series systems using either the USB 2.0 or Ethernet connections. The SD Memory Card slot has many uses including the easy backup and restore of programs and parameters. SD memory card slot USB and Ethernet connections standard Use the USB 2.0 interface or Ethernet to connect directly at the instillation site.
L series Features Program-less device data transfer ■ Simple PLC Communication Setting CPU [Simple PLC communication function*1] Using the programming tool, a simple parameter setting is all that is needed to transfer device data such as production information with no programming required. This function makes it possible to easily establish communications not only with L series, but also Q Series and QnA/A Series controllers.
L series Features Gain more flexibility with an integrated system bus structure Save space in control panels by utilizing the integrated system bus structure. Flexibility in system design is made possible by choosing only the required expansion modules for the application. Expand L series systems with no base unit restrictions L series modules do not require a base unit. The installation space is not restricted by base size, and the system can be installed with minimal required space.
L series Features System expandable according to production equipment scale Up to three extension blocks connectable to the main block using branch and extension modules. A maximum of 40 modules*1 caters a wide range of production equipment and line scale.
L series Features Data logging function The built-in data logging function provides an easy way to collect information for troubleshooting, performance evaluation, and other uses. The included configuration tool makes setting up the data logging function a breeze with a step-by-step wizard like interface. Using GX LogViewer, the captured data is easy to interpret and understand. ■ Configuration tool Select the logging type.
■ File transfer feature* 1 Forward files to an FTP server to manage the data collectively. FTP server Logging file is forwarded CPU Data logging files stored on the SD memory card can be forwarded to an FTP server just by making a simple setting with the LCPU logging Configuration Tool. Maintenance and management work can be reduced by batch-managing multiple logging files.
L series Features Device monitor Built-in I/O monitor Feature rich and easy to use display Error message display (Red backlight) Check the system status and make setting changes directly from the display. Error status is clearly identified and troubleshooting and error investigation can be performed all without the need for any connections or engineering software. Instant error information check Error history and detailed error information is available directly from the display unit.
L series Features CPU The L series has been designed from the ground up to be easy to use I/O The L series module labeling design has been created to ensure clear legibility and identification of information at glance to avoid mistakes. Universal design ■ Regular Gothic font 0 1 2 3 4 5 6 7 8 9 ABCDE 0 1 2 3 4 5 6 7 8 9 ABCDE The space indicated with a red circle has been enlarged. The numbers “3, 6, 8, 9” and the alphabet “C” are clearly distinguishable. Characters are legible even in small print.
L series Features Increase productivity and lower the total cost of ownership. Introducing the next generation of IA programming software: GX Works2 focuses on driving down total cost by including features that speed up commissioning, reduce downtime, improve programming productivity, and provide strong security.
L series Features Time saving programming features Ladders can be easily edited just by choosing from candidates of instructions and labels. The information of arguments are also shown to reduce errors during ladder input. Instruction options Instruction details Instruction usage details CPU I/O Label data type Hold down Ctrl and use the arrow keys (←, →, ↑, ↓) to draw and erase lines. Use Ctrl + Shift + (←, →) to edit continuous lines.
L series Features Use function blocks for common operations Function blocks allow selections of commonly used code to be easily reused and shared among projects. Shared or created function blocks can be added to a program using simple drag and drop operation. Using function blocks effectively results in faster development times with fewer programming mistakes. Use the function block selection window to find and import function blocks to the program.
L series Features Easy project contents search [Cross reference] The cursor position can be used to automatically select a part of the program and perform a cross reference of devices/labels and display a list of the relevant sections. Easily jump from the cross reference results to the relevant parts of the program to confirm the locations. CPU Cross reference information for the device at the cursor location is automatically displayed. Label names may be batch replaced.
L series Features Advanced PLC diagnostics The diagnostics screen provides a wealth of information about the currently connected controller. The main screen allows the operational status of the entire programmable controller to be seen at a glance, allowing the immediate identification of problems. Additional detailed information is available to help with routine maintenance and problem resolution.
Programmable Controller Engineering Software MELSOFT GX Works2 MELSOFT MT Works2 L series Features Motion Controller Engineering Software HMI Screen Creation Software MELSOFT GT Works3 CPU System Management Software MELSOFT Navigator Next Generation Seamless Engineering Environment I/O Robot Programing Software MELSOFT RT ToolBox2 iQ Works is the combination of Mitsubishi engineering software (GX Works2, MT Works2, GT Works 3, RT ToolBox2) that allows for the sharing of design information to im
L series Features MX Component Easily connect personal computer to PLC MX Component is the Active X® control library enables communication from a personal computer to a PLC regardless of communication protocol. Complicated programs for serial and Ethernet communication can be developed with simple steps. Greatly improved development efficiency The wizard style configuration utility facilitates access to the target PLC CPU. Once configured, the conditions are saved.
L series Features MX Sheet MX Sheet is an Excel® software package that enables PLC device data collection. PLC system monitoring, data logging, alarm message collection, system setting, etc. can be done using Excel®. CPU Easy data collection using Excel® I/O Simple and program-less setting [ Step1 ] [ Step2 ] Start the configuration utility, select a function, and set the device conditions. Then, data collection will be started only by arranging the screen and executing the function.
L series Features Harness the power of L series and GOT combined When connected to an L series system, Mitsubishi Graphic Operation Terminals are capable of advanced system maintenance and diagnostic functions that can reduce downtime. Dedicated MELSEC-L series maintenance screen* (Troubleshooting functions for L series) Jump from the L series maintenance screen to the intelligent function module monitor screen *GT16 only.
GOTs enable ladder programs to be edited without the need for a PC. Furthermore, because it is possible to perform write during run operations using the GOT, ladder programs may be corrected without stopping the machine, even if it GT16 GT15 is in operation.
CPU CPU Modules ■ L02CPU Program capacity 20ksteps Number of I/O points 1024points Ethernet USB General Output ■L 02CPU-P ■ L26CPU-BT 16 inputs / 8 outputs Program capacity 20ksteps Number of I/O points 1024points Ethernet USB Built-in I/O Positioning 2 axes Built-in I/O 16 inputs / 8 outputs Program capacity 260ksteps Number of I/O points 4096points Basic operation processing speed 9.5ns Ethernet USB CC-Link Ver.2.
L series Features ■ General specifications General specifications indicate the environmental specifications in which this product can be installed and operated. Unless otherwise specified, these general specifications apply to all L series products. *General specifications of jointly developed products are different from those of MELSEC products. For more information, please refer to the product manuals or contact your local Mitsubishi Electric representative.
CPU ■ CPU module device specifications Item Number of I/O device points L02CPU (number of points available on a program) Number of I/O points Internal relay (M) Latch relay (L) Link relay (B) Timer (T) Retentive timer (ST) Counter (C) Data register (D) Extended data register (D) Link register (W) Extended link register (W) Annunciator (F) Edge relay (V) Link special relay (SB) Link special register (SW) (R) File register (ZR) Step relay (S) Index register/standard device register (Z) Index register (Z
External input signal : Selectable Function High-speed counter CH1 Coincidence output No.1*1 CH2 Coincidence output No.1*1 CH1 Coincidence output No.2*2 CH2 Coincidence output No.
CPU ■ CPU built-in I/O function - high-speed counter specifications Item L02CPU Number of channels Phase Count input signal DC input Differential input Signal level Maximum counting speed Counting range Model Counter External input 1 phase 2 phases Min. phase differential for 2-phase input DC input Phase Z (preset) Differential input Function start Latch Minimum count pulse width (Duty ratio 50%) Response time L26CPU-PBT 5μs 24VDC 4.1mA (TYP.
L series Features ■ CPU built-in Ethernet function specifications L02CPU L02CPU-P L26CPU-BT 100 or 10 Mbps Full-duplex or half-duplex Base band 100 m Cascade connection: Up to four Cascade connection: Up to two L26CPU-PBT Total of 16 for socket communications, MELSOFT connections, and MC protocol.
CPU Branch / Extension Module ■L 6EXB For extension system (branch) ■L 6EXE For extension system (extension) ■ Specifications for branch and extension modules Item 5VDC internal current consumption Weight L6EXB [ Branch module ] 0.08A 0.12kg L6EXE [ Extension module ] 0.08A 0.13kg ■ Specifications for extension cables Item LC06E 0.6m 0.19kg Cable length Weight LC10E 1.0m 0.23kg LC30E 3.0m 0.
RS-232 Adapter RS-232 L series Features ■ L6ADP-R2 *For connection of GOT Transmission speed 115.2kbps CPU ■ RS-232 adapter specifications Item Maximum data transmission speed 5VDC internal current consumption Weight Specification 115.2kbps 0.02A 0.10kg I/O END Cover with Error Terminal ■ L6EC-ET Analog / Temperature Control Error output Relay Specification 24VDC 0.5A 5VDC, 1mA 10ms or less 12ms or less 20 million times or more Rated switching voltage/current: 10 million times or more — — 0.
I/O Input Modules ■ LX10 AC input NEW ■ LX28 AC input NEW ■ LX40C6 DC input Number of inputs 16points Rated input voltage 100 to 120VAC Response time 20ms or less External connections 18-point terminal block Number of inputs 8points Rated input voltage 100 to 240VAC Response time 20ms or less External connections 18-point terminal block Number of inputs 16points Rated input voltage 24VDC Response time 1 to 70ms or less ■ LX41C4 DC input ■ LX42C4 DC input Rated input voltage 24VDC Respon
LX40C6 LX41C4 LX42C4 All DC input modules are capable of using both positive or negative common connections; separate modules are not necessary. LX40C6 LX41C4 LX42C4 For all DC input modules, match the response speed to the connected devices. Choose from 1, 5, 10, 20 or 70ms.
I/O Output Modules ■ LY10R2 ■L Y20S6 Contact output Triac output NEW Number of outputs 16points Rated switching current 2A/point Max. switching load 264VAC/125VDC Number of outputs 16points Rated load voltage 100 to 240VAC Response time 12ms or less Max. load current 0.6A/point 1ms + 0.
LY40NT5P LY41NT1P LY42NT1P LY40PT5P LY41PT1P LY42PT1P Modules are built with countermeasures in case of external load short-circuits to protect against over-current and overheating.
I/O [Transistor output module (Sink type)] Item Number of output points Rated load voltage Maximum load current Maximum inrush current Leakage current at OFF LY40NT5P 16 points 0.5A/point, 5A/common 0.2VDC(TYP.)0.5A, 0.3VDC(MAX.)0.
L series Features ■ How to read the product code L Y 4 0 NT 5 P ➀ ➁ ➂ ➀ ➄ ➅ Item Code X Y Item Code Module type CPU Number ➃ Specification Input Output Specification Number Voltage specification Number ➂ Code 0 1 2 8 Specification 16 points 32 points 64 points 8 points Item Code Blank C NT PT R S Specification AC input DC input (positive / negative shared common) Transistor output module (Sink type) Transistor output module (Source type) Contact output Triac output Item Code I/O type
Analog / Temperature Control Analog Input Module ■ L60AD4 Number of inputs 4 points (channels) Input voltage Input current -10 to 10VDC 0 to 20mADC Conversion speed 20μs/ch 1/20000 Resolution Accuracy ±0.
L60AD4 [ Logging function*1 ] Data is continuously collected at the set cycle and stored in the buffer memory. Data stored in the buffer memory can be used for debugging, and to periodically confirm data variations.
Analog / Temperature Control Extend the detection method according to applications L60AD4 [ Input signal error detection extension function*1 ] Using this function, the detection method of the input signal error detection function can be extended. Use this function to detect an input signal error only at the lower or upper limit, or to execute the disconnection detection. [ Input range extended mode function*1 ] The input range can be extended.
L60AD4 L60DA4 GX Works2 contains support tools to help configure intelligent function modules. All of the required information to configure and revise complicated parameter settings is included so it is not necessary to reference a manual. L series Features Configure modules without the need to reference a manual CPU Setting details are listed so referencing the manual is unnecessary.
Analog / Temperature Control Temperature Control Modules ■L 60TCTT4 Thermocouple 4 Temperature input points points (channels) Standard control Self-tuning function Peak current suppression function Temperature input mode Temperature control mode Heating-cooling control Simultaneous Selectable temperature sampling cycle rise function GX Works2 Error history ■L 60TCTT4BW Thermocouple 4 Temperature input points points (channels) Standard control Heating-cooling control Self-tuning function
L series Features Highly stable temperature control [ Standard control/heating and cooling control ] Prevent overheating and overcooling in devices which require a high level of temperature stability, such as in an extrusion molding machine. In addition to standard temperature control (heating or cooling), control of cooling may be performed. Furthermore, mix control (a combination of heating and cooling control) can be performed.
Analog / Temperature Control Ensures uniform temperature control [ Simultaneous temperature rise function ] Ensures uniform temperature control by synchronizing the temperature arrival times from multiple loops. Perform a uniform temperature rise using two or more control loops without going over temperature or resulting in unexpected thermal expansion. A "no idling" format increases energy efficiency and reduces running costs.
■ Specifications L60TCTT4 L60TCTT4BW L60TCRT4 L60TCRT4BW Transistor output Number of temperature input points 4 points (ch) Thermocouple Applicable temperature sensors Resistive thermal device Ambient temperature: 25 ± 5°C Indication accuracy Accuracy*1 L series Features Item Control output Full scale × (±0.3%) Ambient temperature: 0 to 55°C Full scale × (±0.
Simple Motion High iQ Platform compatible motion controller Servo function and performance Stand-alone motion controller Simple motion module Simple motion module LD77MH4 LD77MH16 Positioning module LD75D4 LD75D2 LD75D1 Introducing simple motion control, evolved LD75P4 LD75P2 LD75P1 The MELSEC-L series includes simple motion and general positioning modules.
L series Features Countless applications are possible A variety of control types including positioning control, speed control, torque control, cam control and synchronous control can be implemented easily with simple parameter settings and a sequence program.
Simple Motion Perfect synchronous control is easy to achieve Replace mechanical gears, shafts, speed change gears, cams, etc. and generate synchronous control operations using software. •• Complicated programs are unnecessary for synchronous control because it can be implemented easily using parameter settings. •• Start and stop synchronous control for each axis. Use the synchronous control axis and positioning control axis together.
■ Specifications Control system Linear control Position control 1-axis speed control, 2-axis speed control, 3-axis speed control, 4-axis speed control INC mode, ABS mode INC mode Changing to a new current value using the positioning data , Changing to a new current value using the start No.
Positioning Positioning Modules ■L D75P1 ■L D75D1 Open collector Differential driver NEW NEW Number of control axes 1 axis Max. output pulse 200kpulse/s Number of control axes 1 axis Max. output pulse 4Mpulse/s Positioning data 600 data/axis Max. connection distance 2m Positioning data 600 data/axis Max.
LD75D1 LD75D2 LD75D4 Control high resolution devices such as linear servos and direct drive motors without compromising speed. Max. output pulse Max.
Positioning ■ Specifications [ Open collector ] Item Number of control axes Interpolation function Control system Control unit Positioning data Backup PTP*1 control Positioning Speed-position switching control control Position-speed switching control system Path control In ABS system Positioning In INC system control range Positioning In speed-position switching control control (INC mode)/ position-speed switching control In speed-position switching control (ABS mode)*2 Speed command Acceleration/deceler
Item Number of control axes Interpolation function Control system Positioning data Backup PTP*1 control Positioning Speed-position switching control control Position-speed switching control system Path control Positioning In INC system control range Positioning In speed-position switching control control (INC mode)/ position-speed switching control Speed command Acceleration/deceleration system selection Acceleration/deceleration time Starting time*3 High-Speed Counter Pulse output method Differentia
High-Speed Counter High-Speed Counter Modules ■ LD62 DC input ■ LD62D Differential input Number of channels 2ch 5/12/24VDC input Max. counting speed 200kpulse/s Linear counter function Ring counter function Coincidence output function Disable count function Latch counter Sampling counter Periodic pulse function function counter function Preset function Number of channels 2ch Differential driver input Max.
■ Specifications LD62 [DC input] Maximum counting speed*1 Counting range Type 10kpulse/s, 100kpulse/s, 200kpulse/s 10kpulse/s, 100kpulse/s, 200kpulse/s, 500kpulse/s 1-phase input (multiple of 1/2), CW/CCW, 2-phase input (multiple of 1/2/4) EIA Standard RS-422-A differential type line driver level 5/12/24VDC 2 to 5mA (Equivalent with AM26LS31 (manufactured by Texas Instruments Japan Limited)) 200kpulse/s 500kpulse/s -2147483648 to 2147483647 UP/DOWN preset counter and ring counter functions Minimum count
Serial Communication Serial Communication Modules ■ LJ71C24 Interface Interface RS-232 RS-422/485 Communication system Communication system MC protocol Max. transmission speed 230.4kbps* Communication system Communication system Communication system Communication system Pre-defined protocol Nonprocedural protocol Bidirectional protocol GX Works2 Error history *Available for only channel 1 ■ LJ71C24-R2 Interface RS-232 x 2 Communication system MC protocol Max. transmission speed 230.
L series Features Easy to prepare and edit predefined protocol Even if the device to be connected is not contained in the predefined protocol library, the device can be added easily. CPU Click “Add button.” Select “Add New.” Item has been added. The contents of the prepared predefined protocol can be displayed in a list form. The protocol can be edited easily. I/O Analog / Temperature Control The data can be edited as needed.
Network Seamless integration of multiple networks Today there is an increasing demand from production facilities for high speed control, effective management of data, flexible wiring, easy parameter settings, and predictive maintenance. To answer these demands, Mitsubishi Electric has teamed up with the CC-Link Partner Association to provide reliable, openstandards networks that operate seamlessly with one another.
Seamless communication Ethernet Enterprise level network Within the factory Control level network Within the production line Device level network SERVO SYSTEM CONTROLLER NETWORK Within the machine or panel CPU L series combines enterprise, control, and device level networks together through Ethernet, MELSECNET/H, and CC-Link networks to allow easy access to information, no matter where it resides on the network.
Network CC-Link IE Field Network Master/Local Module ■ LJ71GF11-T2 Master/ local station Transmission speed 1Gbps Remote I/O 16384 points Remote register 8192 words CC-Link IE Field * Sequence CPUs whose first five serial number digits are "13012" or later are required. Easy to configure settings Network parameters are configured using the engineering tool, GX Works2. Only the master station needs to be configured, thereby greatly simplifying the network setup.
■ LJ72GF15-T2 Intelligent device station Remote register 1024 words Remote I/O 2048 points Max. number of connected modules 120 RAS function CPU RAS function Transmission speed 1Gbps L series Features CC-Link IE Field Network Head Module RAS function System monitor Remote RESET Self-diagnosis CC-Link IE Field *END cover is included.
Network CC-Link Master/Local Module ■ LJ61BT11 Master/ local station Max. transmission speed 10Mbps Remote I/O Remote register 2048 words* 8192 points* Local station CC-Link Ver.2.0 Standby master Transmission speed station function auto-tracking function *Link points for CC-Link Ver.2.
■L J61CL12 Master station Max. transmission speed 2.5Mbps CC-Link/LT No parameter settings L series Features CC-Link/LT Master Module Remote I/O 1024 points* Remote station Transmission speed auto-tracking function CPU *In the 16-point mode I/O High speed equipment response ■ CC-Link/LT link scan time (using a transmission speed of 2.5Mbps) 2.5 16 point mode 2.0 8 point mode 4 point mode 1.5 1.0 0.
Network Ethernet and CC-Link IE Field related products ■ Wireless LAN Adapter Ethernet NZ2WL-US (U.S.A)* * , NZ2WL-EU (Europe)* 1*2, NZ2WL-CN (China)* 1*2, NZ2WL-KR (Korea)* 1*2, NZ2WL-TW (Taiwan)* 1*2 1 2 Features • Wireless LAN (Ethernet) in the factory provides flexibility in installing new line or alteration layouts.Wireless saves your wiring costs. • Simply installing wireless LAN adapters makes existing FA equipment wireless. • Compatible with the latest security standards of WPA2/WPA.
CC-Link IE Field L series Features ■ Industrial Switching HUB Ethernet NZ2EHG-T8 / NZ2EHF-T8*1 Features • NZ2EHG-T8 is compatible with transmission rates of 10 Mbps, 100 Mbps, and 1 Gbps. • NZ2EHF-T8 is compatible with transmission rates of 10 Mbps and 100 Mbps. CPU • These switching hubs comply with IEEE802.3ab (1000 BASE-T), IEEE802.3u(100 BASETX), IEEE802.3 (10 BASE-T) standards. • AutoMDI/MDI-X and auto-negotiation are available.
External Dimension Diagrams CPU Modules 4 4 L02CPU, L02CPU-P 90 90 45 END cover (accessory) 4 4 4 (45) DIN rail center 13 70 95 4 4 L26CPU-BT, L26CPU-PBT 90 90 45 END cover (accessory) 13 98.5 118 Extension Module L6EXB L6EXE END cover (accessory) DIN rail center 90 90 90 45 45 4 4 Branch Module 4 95 4 4 4 (45) DIN rail center (45) (45) DIN rail center 95 28.5 4 4 4 4 4 28.5 95 13 Extension Cable 60.1 LC06E, LC10E, LC30E 32.0 11.
Power Supply Modules RS-232 adapter L6ADP-R2 90 90 45 45 4 L61P, L63P DIN rail center (45) (45) DIN rail center 4 45 4 95 109 4 4 28.5 95 Display Unit L6EC-ET L6DSPU (45) DIN rail center ERR. 24VDC 0.5A 95 112.5 L 4 + − 4 50 90 45 4 END cover with error terminal 28.5 10 15 (2.3) 45 I/O Modules LX28 NEW , LX40C6, LY10R2, LY20S6 NEW , LY40NT5P, LY40PT5P LX41C4, LY41NT1P, LY41PT1P 4 NEW , 90 90 45 45 4 LX10 DIN rail center 95 4 4 4 117 28.
External Dimension Diagrams Analog I/O Modules 90 45 4 L60AD4, L60DA4 4 95 4 (45) DIN rail center 117 28.5 Temperature Control Modules L60TCTT4BW, L60TCRT4BW 90 90 45 45 4 4 L60TCTT4, L60TCRT4 DINレール中心 95 4 4 4 117 28.5 95 4 (45) (45) DIN rail center 117 57.0 Simple Motion Module 90 45 4 LD77MH4, LD77MH16 4 95 98.
Positioning Modules LD75P2 LD75D1 NEW NEW , LD75D2 NEW (45) DINレール中心 (45) DINレール中心 90 45 90 45 4 NEW , 4 LD75P1 4 4 4 4 45 95 90 45 90 45 4 LD75D4 4 LD75P4 45 95 (45) DIN rail center (45) DIN rail center 4 4 4 4 45 95 45 95 High-Speed Counter Modules 90 45 4 LD62, LD62D 4 4 (45) DIN rail center 28.5 95 Serial Communication Modules LJ71C24-R2 90 90 45 45 4 4 LJ71C24 DIN rail center (45) (45) DIN rail center 118 4 28.5 4 95 4 4 95 4 28.
External Dimension Diagrams LJ71GF11-T2 LJ61BT11 90 45 90 45 4 CC-Link Master/Local Module 4 CC-Link IE Field Network Master/Local Module DIN rail center 4 4 4 95 45 95 4 (45) (45) DIN rail center 118 28.5 CC-Link/LT Master Module 90 45 4 LJ61CL12 4 95 4 (45) DIN rail center 28.
MEMO 72
Reaching out to the world using a global network Global FA center "Mitsubishi Electric Global FA centers" have been established in various countries around the world to cover the Americas, Europe, and Asia. FA centers help to ensure compliance with the certifications and regulations of different regions, initiate product development in response to local demands, and provide full-time, professional customer service. UK FA Center European FA Center Mitsubishi Electric Europe B.V.
to provide comprehensive customer support. FA center FA center satellite (China) Mechatronics service center (China) Sales and Service office Factory location Development center Russian FA Center Korean FA Center Mitsubishi Electric Europe B.V. Russian Branch St.Petersburg office Piskarevsky pr. 2, bld 2, lit "Sch", BC "Benua", office 720; 195027, St. Petersburg, Russia Tel: +7-812-633-3497 / Fax: +7-812-633-3499 Area covered: Russia Mitsubishi Electric Automation Korea Co., Ltd.
Product List *Refer to the product user manuals for information about compatible modules, restrictions, etc., before using the products. *Contact your local Mitsubishi Electric sales office or representative for the latest information about MELSOFT software versions and compatible operating systems.
MELSEC-L series [ Legend ] Product Model Analog input L60AD4 Analog output L60DA4 L60TCTT4 Thermocouple L60TCTT4BW Temperature Control L60TCRT4 RTD L60TCRT4BW LD77MH4 Intelligent function module Simple motion LD77MH16 LD75P1 NEW Open collector LD75P2 NEW LD75P4 Positioning LD75D1 NEW Differential driver LD75D2 NEW LD75D4 LD62 High-speed counter LD62D Serial communication CC-Link IE Field network Network CC-Link CC-Link/LT LJ71C24 LJ71C24-R2 LJ71GF11-T2 LJ72GF15-T2*2 LJ61BT11 LJ61CL12 DB : D
MELSOFT*1 — Programming Tool Product GX Works2 GX Developer*2 Model Outline SW1DNC-GXW2-E Programmable controller engineering software (Functions integrated software: Programming, simulation, module settings, and monitoring) SW8D5C-GPPW-E Programmable controller programming software SW8D5C-GPPW-EV Programmable controller programming software (upgrade) FA engineering software*3 • System Management Software: MELSOFT Navigator MELSOFT Navigator is a comprehensive system configuration solution that serv
Microsoft, Windows, Windows Vista are registered trademarks of Microsoft Corporation in the United States and other countries. Ethernet is a trademark of Xerox Corporation. SDHC logo is a trademark. All other company names and product names used in this document are trademarks or registered trademarks of their respective companies.
Mitsubishi Electric Programmable Controllers Precautions before use This publication explains the typical features and functions of the products herein and does not provide restrictions and other information related to usage and module combinations. Before using the products, always read the product user manuals.