7) Disconnect the 3-pin connector of the instrument
panel harness from the junction block. Draw out the
No. 3 terminal from the connector and install the
terminal with red/green wire of the harness to
that cavity. Reconnect the connector to the junction
block.
8) Disconnect the connector half on the 1-pin connector
(male) of the harness . Install the terminal drawn
out in step 4) to that connector half and reconnect it
to its original position.
9) Wrap the 1-pin connector with the urethane sheet
C to prevent it from rattling.
10) Route the harness leading to the 1-pin connector
along the instrument panel harness and secure them
using the tie-wrap .