M-Series MZ-GE Engineering Manual
Table Of Contents
- Contents
- 1. INDOOR UNITS
- 2. OUTDOOR UNITS
- 3. SYSTEM
- 3-1. SPECIFICATIONS
- 3-2. EXTERNAL DIMENSIONS
- 3-3. CENTER OF GRAVITY
- 3-4. ELECTRICAL WIRING DIAGRAMS
- 3-5. REFRIGERANT SYSTEM DIAGRAMS
- 3-6. CAPACITY CORRECTION CURVE BY TEMPERATURE
- 3-7. CAPACITY CORRECTION TABLE BY TEMPERATURE
- 3-8. CAPACITY CORRECTION CURVE BY REFRIGERANT PIPING LENGTH
- 3-9. CAPACITY CORRECTION TABLE BY REFRIGERANT PIPING LENGTH
- 3-10. CHARGE CALCULATIONS
- 3-11. AIR FLOW DATA
- 3-12. SOUND PRESSURE LEVELS
- 3-13. STANDARD OPERATION RANGE
- 3-14. MAXIMUM HEATING CAPACITY IN LOW AMBIENT TEMPERATURE
- 3-15. ACCESSORIES
MSZ-GENA2-14
M-Series - MSZ/MUZ-GENA2 Heat Pump Systems (August 2014)
Due to continuing improvement, above specication may be subject to change without notice.
© 2014 Mitsubishi Electric US, Inc.
MUZ-GE09NA2 MUZ-GE12NA2 MUZ-GE15NA2
3-2. EXTERNAL DIMENSIONS
Liquid pipe :1/4 (flared)
Gas pipe :3/8 (flared) (GE09/12)
1/2 (flared) (GE15)
6-23/32
2
5-7/8
2-23/32
1-3/4
15-3/4
12 ~ 12-3/4
13-9/16
11/16
1-9/16
7/8
21-5/8
11-1/32
13/32
31-1/2
19-11/16
5-15/16
11-29/32
17/3229/32 11-1/4
Air in
handle
Air in
Air out
2- 3/8 13/16 Oval hole
Drain hole
ø
1-5/8 (
GE09/12/15NA2
)
Drain hole
ø
1-5/16 (
GE09/12/15NAH2
)
REQUIRED SPACE
14 in. or more
8 in. or more *2
4 in. or more
4 in. or more
*1 4 in. or more when front
and sides of the unit are clear
*2 When any 2 sides of left, right
and rear of the unit are clear
Clear *1