M-Series MZ-GE Engineering Manual
Table Of Contents
- Contents
- 1. INDOOR UNITS
- 2. OUTDOOR UNITS
- 3. SYSTEM
- 3-1. SPECIFICATIONS
- 3-2. EXTERNAL DIMENSIONS
- 3-3. CENTER OF GRAVITY
- 3-4. ELECTRICAL WIRING DIAGRAMS
- 3-5. REFRIGERANT SYSTEM DIAGRAMS
- 3-6. CAPACITY CORRECTION CURVE BY TEMPERATURE
- 3-7. CAPACITY CORRECTION TABLE BY TEMPERATURE
- 3-8. CAPACITY CORRECTION CURVE BY REFRIGERANT PIPING LENGTH
- 3-9. CAPACITY CORRECTION TABLE BY REFRIGERANT PIPING LENGTH
- 3-10. CHARGE CALCULATIONS
- 3-11. AIR FLOW DATA
- 3-12. SOUND PRESSURE LEVELS
- 3-13. STANDARD OPERATION RANGE
- 3-14. MAXIMUM HEATING CAPACITY IN LOW AMBIENT TEMPERATURE
- 3-15. ACCESSORIES
M-Series - MSZ/MUZ-GENA2 Heat Pump Systems (August 2014)
MSZ-GENA2-11
© 2014 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specication may be subject to change without notice.
3-1. SPECIFICATIONS
Efciency ratings
Outdoor Unit Indoor Unit SEER EER HSPF
COP
@ 47° F
COP
@ 17° F
Energy
Star
Tax
Credit
WALL-MOUNT HEAT PUMP
MUZ-GE09NA2 MSZ-GE09NA-8 23.20 13.6 11.0
4.20 2.76 Yes Yes
MUZ-GE12NA2 MSZ-GE12NA-8 22.70 12.5 11.4
3.61 2.87 Yes Yes
MUZ-GE15NA2 MSZ-GE15NA-8 21.60 13.0 11.2
3.30 2.88 Yes Yes
MUZ-GE18NA-1 MSZ-GE18NA-8 19.20 10.5 10.0 3.32 2.70
MUZ-GE24NA MSZ-GE24NA 19.00 12.5 10.0 3.46 2.64
Yes Yes
Note:
Efciency values based on AHRI 210/240 test method.
Model name
MUZ-GE24NA
Capacity
Rated (Minimum~Maximum)
Cooling 1 Btu/h 22,500(8,200 ~ 31,400)
Heating 47 1 Btu/h 27,600(7,500 ~ 36,900)
Capacity
Rated (Maximum)
Heating 17 2 Btu/h 16,000 (24,600)
Power consumption
Rated (Minimum~Maximum)
Cooling 1 W
1,800 (570
~ 3,580)
Heating 47 1 W
2,340 (520
~ 3,650)
Power consumption Heating 17 2 W 1,770 (3,290)
EER 1 [SEER] 3 Cooling 12.5 [19.0]
HSPF IV 4 Heating 10.0
COP Heating 1 3.46
Power supply V , phase , Hz 208/230 , 1 , 60
Max. fuse size (time delay) A 20
Min. circuit ampacity A 17.1
Fan Motor (ECM) F.L.A 0.93
Compressor
Model SNB172FQKMT
R.L.A 12.9
L.R.A 16.1
Refrigeration oil cc.
(Model)
0.40 (FV50S)
Refrigerant control Linear expansion valve
Sound level 1
Cooling dB(A) 55
Heating dB(A) 55
Defrost method Reverse Cycle
Dimensions
W in. 33-1/16
D in. 13
H in. 34-5/8
Weight Ib. 119
External nish Munsell 3Y 7.8/1.1
Remote controller Wireless type
Control voltage
(by built-in transformer)
VDC 12 - 24
Refrigerant piping Not supplied
Refrigerant pipe size
(Min. wall thickness)
Liquid in. 3/8 (0.0315)
Gas in. 5/8 (0.0315)
Connection method
Indoor Flared
Outdoor Flared
Between the indoor
& outdoor units
Height difference ft. 50
Piping length ft. 100
Refrigerant charge (R410A) 4 lb. 3 oz.
NOTE: Test conditions are based on ARI 210/240.
1: Rating conditions (Cooling) — Indoor: 80˚FDB, 67˚FWB, Outdoor: 95˚FDB, (75˚FWB) Rated frequency
(Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 47˚FDB, 43˚FWB Rated frequency
2: (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 17˚FDB, 15˚FWB Maximum frequency