M-Series MUZ-GE Technical & Service Manual
51
Part name Check method and criterion Figure
Outdoor fan motor
Measure the resistance between lead wires using a tester.
(Temperature: -4 ~ 104°F (-20 ~ 40°C))
Color of lead wire
Normal (Ω)
GE09/12 GE15 GE18/24
RED – BLK
BLK – WHT
WHT – RED
28 ~ 40 11 ~ 16
W
U
V
WHT
RED BLK
R. V. coil (21S4)
(MUZ)
Measure the resistance using a tester.
(Temperature: 14 ~ 104°F (-10 ~ 40°C))
Normal (kΩ)
0.97 ~ 1.38
Expansion valve coil
(LEV)
Measure the resistance using a tester.
(Temperature: 14 ~ 104°F (-10 ~ 40°C))
MUZ-GE09/12/15/18NA
MUZ-GE09/12/15NA2
MUZ-GE09/12/15/18NAH
MUZ-GE09/12/15NAH2
MUY-GE09/12/15/18NA
MUY-GE09/12/15NA2
Color of lead wire Normal (Ω)
WHT – RED
37 ~ 54
RED – ORN
YLW – BRN
BRN – BLU
LEV
WHT
RED
ORN
YLW
BRN
BLU
Measure the resistance using a tester.
(Temperature: 14 ~ 104°F (-10 ~ 40°C))
MUZ-GE24NA, MUY-GE24NA
Color of lead wire Normal (Ω)
RED – ORN
37 ~ 54
RED – WHT
RED – BLU
RED – YLW
RED
(+12V)
YLW
BLU
WHT
ORN
LEV
Defrost heater
MUZ-GE•NAH
Measure the resistance using a tester.
(Temperature: 14 ~ 104°F (-10 ~ 40°C))
Normal (Ω)
349 ~ 428
OBH549G