M-Series MSZ-GE15 Submittal
M-SERIES
Specications are subject to change without notice.
© 2014 Mitsubishi Electric US, Inc.
Job Name:
System Reference: Date:
SPECIFICATIONS
Cooling Capacity*............................14,000 Btu/h
Heating Capacity*............................18,000 Btu/h
(For data on specic indoor units [all ducted, all non-ducted,
and both ducted and non-ducted] combinations, see the MXZ
Technical and Service Manual.)
Electrical Requirements
Power Supply ....................208 / 230V, 1-Phase, 60 Hz
MCA .............................................. 1 A
Voltage
Indoor - Outdoor S1-S2 ......................AC 208 / 230V
Indoor - Outdoor S2-S3 ...........................DC ±24V
Indoor - Remote Controller.....................MKH1 DC 3V
PAR-31MAA DC 12V
PAC-YT53CRAU DC 12V
Blower Motor (ECM)............................0.76 F.L.A.
Airow (Quiet - Lo - Med - Hi - Super Hi)
Cooling .....................205 - 272 - 335 - 420 - 533 Dry CFM
170 - 237 - 300 - 385 - 498 Wet CFM
Heating ...................205 - 247 - 304 - 367 - 463 CFM
Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi)
Cooling ....................... 26 - 32 - 38 - 44 - 49 dB(A)
Heating ....................... 26 - 30 - 35 - 40 - 46 dB(A)
DIMENSIONS UNIT INCHES / MM
W 31-7/16 / 799
D 9-1/8 / 232
H 11-5/8 / 295
Weight. ....................................22 lbs. / 10 kg
External Finish ....................Munsell No. 1.0Y 9.2 / 0.2
Field Drainpipe Size O.D.....................5/8" / 15.88 mm
Refrigerant Type .................................. R410A
Refrigerant Pipe Size O.D.
Gas Side ................................1/2" / 12.7 mm
Liquid Side...............................1/4" / 6.35 mm
Connection Method ................................Flared
SUBMITTAL DATA: MSZ-GE15NA-8
15,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ MULTI-ZONE HEAT-PUMP SYSTEMS
Indoor Unit: MSZ-GE15NA-8
ACCESSORIES
Indoor Unit
□ Condensate Pump (230V; SI3100-230)
Controller Options
□ Wireless Wall-mounted Remote Controller Kit (MHK1)*
□ Portable Central Controller (MCCH1)*
□ Outdoor Air Sensor (MOS1)*
□ Wired Wall-mounted Controller
(PAR-31MAA requires MAC-333IF)*
□ Simple MA Remote Controller
(PAC-YT53CRAU requires MAC-333IF)*
*See Submittal for information on each option.
□ System Control Interface (MAC-333IF)
□ Remote Temperature Sensor (M21-JKO-307)
□ Lockdown Bracket for Hand-held Controller (RCMKP1CB)
GENERAL FEATURES
• Wall-mounted indoor unit
• Standard Hybrid Catechin Prelter is included with indoor unit
• Quiet operation
• Auto fan speed control: Quiet, Low, Medium, High, and Super High
• Hand-held Wireless Remote Controller
• Indoor unit powered from outdoor unit using A-Control
• Auto restart following a power outage
• Base heater is available as an option
• Anti-allergy Enzyme Filter
• Limited warranty: ve years parts and seven years compressor
Wireless Remote
Controller
* Rating Conditions per AHRI Standard
Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB
Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB
Heating at 47ºF | Indoor: 70º F (21º C) DB / 60º F (16º C) WB
Heating at 47ºF | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB