MSZ-GE-NA-50
M-Series - MSZ/MUZ-GE-NA Heat Pump Systems (August 2014)
Due to continuing improvement, above specication may be subject to change without notice.
© 2014 Mitsubishi Electric US, Inc.
3-14. MAXIMUM HEATING CAPACITY IN LOW AMBIENT TEMPERATURE
HEATING CAPACITY
-13.0 -4.0 5.0 14.0 23.0 32.0 41.0 50.0 69.8
0%
20%
40%
60%
80%
100%
120%
-15 -5 5 15 25 35 45
Outdoor Temperature Degrees (
o
F)
% Heating Capacity
34% 48% 63% 77% 88% 97% 100% 100% 100%
Outdoor Temperature Degrees (
o
F)
% Heating Capacity
MUZ-GE18NA
MUZ-GE24NA
MUZ-GE24NA
MUZ-GE24NA MUZ-GE24NA
MUZ-GE24NA
5000
10000
15000
20000
25000
30000
35000
40000
45000
50000
Heating Max Capacity (Btu/h)
HEATING MAX CAPACITY
DB (
o
F)
-13.0 -4.0 5.0 14.0 23.0 32.0 41.0 50.0 69.8
Q (Btu/h) 15010 18422 21835 25248 27047 28153 29259 38899 46406
W(kW) 2.85 3.00 3.15 3.25 3.35 3.50 3.60 3.70 3.80
COP 5.27 6.14 6.93 7.77 8.07 8.04 8.13 10.51 12.21
0
5000
10000
-15 -5 5 15 25 35 45 55 65 75
DB (
o
F)