M-Series MSZ-GE Engineering Manual
Table Of Contents
- Contents
- 1. INDOOR UNITS
- 2. OUTDOOR UNITS
- 3. SYSTEM
- 3-1. SPECIFICATIONS
- 3-2. EXTERNAL DIMENSIONS
- 3-3. CENTER OF GRAVITY
- 3-4. ELECTRICAL WIRING DIAGRAMS
- 3-5. REFRIGERANT SYSTEM DIAGRAMS
- 3-6. CAPACITY CORRECTION CURVE BY TEMPERATURE
- 3-7. CAPACITY CORRECTION TABLE BY TEMPERATURE
- 3-8. CAPACITY CORRECTION CURVE BY REFRIGERANT PIPING LENGTH
- 3-9. CAPACITY CORRECTION TABLE BY REFRIGERANT PIPING LENGTH
- 3-10. CHARGE CALCULATIONS
- 3-11. AIR FLOW DATA
- 3-12. SOUND PRESSURE LEVELS
- 3-13. STANDARD OPERATION RANGE
- 3-14. MAXIMUM HEATING CAPACITY IN LOW AMBIENT TEMPERATURE
- 3-15. ACCESSORIES
M-Series - MSZ/MUZ-GE-NA Heat Pump Systems (August 2014)
MSZ-GE-NA-41
© 2014 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specication may be subject to change without notice.
3-11. AIR FLOW DATA
● The air coverage is the figure up to the position where the air speed is 1 ft./s., when air is blown out horizontally
from the unit properly at the High speed position.
The coverage should be used only as a general guideline since it varies according to the size of the room and
furniture arranged inside the room.
Model name Mode Function
Airow
(CFM)
Air speed
(ft./s.)
Coverage
(ft.)
MSZ-GE06NA-8
HEAT Dry 406 20.6 29.5
COOL
Dry 321 16.3 23.5
Wet 286 14.5 21.0
MSZ-GE09NA-8
HEAT Dry 406 20.6 29.5
COOL
Dry 321 16.3 23.5
Wet 286 14.5 21.0
MSZ-GE12NA-8
HEAT Dry 406 20.6 29.5
COOL
Dry 321 16.3 23.5
Wet 286 14.5 21.0
MSZ-GE15NA-8
HEAT Dry 463 23.4 33.5
COOL
Dry 420 21.3 30.5
Wet 385 19.5 28.0
MSZ-GE18NA-8
HEAT Dry 512 25.9 36.9
COOL
Dry 420 21.3 30.5
Wet 385 19.5 28.0
MSZ-GE24NA
HEAT Dry 738 18.0 36.9
COOL
Dry 738 18.0 36.9
Wet 661 16.1 31.9
Outlet Air Speed And Coverage