3-7. CAPACITY CORRECTION TABLE BY TEMPERATURE
(1) Cooling Capacity
(1) MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA-1 MUZ-GE18NA-1
Model
Indoor air Outdoor intake air DB temperature (˚F)
IWB (˚ F)
75 85 95 105 115
TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC
MUZ-GE09NA
71 11.0 7.6 0.59 10.3 7.1 0.64 9.7 6.6 0.69 9.0 6.2 0.73 8.3 5.7 0.76
67 10.4 8.6 0.55 9.7 8.0 0.61 9.0 7.4 0.66 8.4 6.9 0.70 7.7 6.3 0.73
63 9.8 9.4 0.53 9.1 8.7 0.58 8.5 8.1 0.63 7.7 7.3 0.67 7.0 6.7 0.70
MUZ-GE12NA
71 14.7 8.9 0.85 13.7 8.3 0.94 12.9 7.8 1.01 12.0 7.3 1.06 11.0 6.7 1.10
67 13.9 10.3 0.81 13.0 9.6 0.89 12.0 8.9 0.96 11.2 8.3 1.02 10.3 7.6 1.07
63 13.1 11.4 0.77 12.1 10.6 0.85 11.3 9.9 0.92 10.3 9.0 0.98 9.4 8.2 1.02
MUZ-GE15NA-1
71 17.2 11.4 0.96 16.0 10.7 1.05 15.1 10.0 1.13 14.0 9.3 1.19 12.9 8.6 1.24
67 16.2 13.0 0.91 15.1 12.1 1.00 14.0 11.2 1.08 13.0 10.4 1.14 12.0 9.6 1.20
63 15.3 14.2 0.86 14.1 13.2 0.96 13.2 12.3 1.03 12.0 11.2 1.10 10.9 10.2 1.14
MUZ-GE18NA-1
71 21.1 12.2 1.46 19.7 11.4 1.60 18.5 10.7 1.72 17.2 9.9 1.81 15.8 9.1 1.89
67 20.0 14.2 1.38 18.6 13.2 1.52 17.2 12.2 1.64 16.0 11.4 1.74 14.7 10.4 1.82
63 18.7 15.8 1.31 17.4 14.7 1.45 16.2 13.6 1.57 14.7 12.4 1.67 13.4 11.3 1.74
NOTE
: 1. IWB: Intake air wet-bulb temperature
TC: Total Capacity (×10
3
Btu/h)
SHC: Sensible Heat Capacity (×10
3
Btu/h)
TPC: Total Power Consumption (kW)
2. SHC is based on 80˚F of indoor Intake air DB temperature.