M-Series MSZ-GE Engineering Manual
Table Of Contents
- Contents
- 1. INDOOR UNITS
- 2. OUTDOOR UNITS
- 3. SYSTEM
- 3-1. SPECIFICATIONS
- 3-2. EXTERNAL DIMENSIONS
- 3-3. CENTER OF GRAVITY
- 3-4. ELECTRICAL WIRING DIAGRAMS
- 3-5. REFRIGERANT SYSTEM DIAGRAMS
- 3-6. CAPACITY CORRECTION CURVE BY TEMPERATURE
- 3-7. CAPACITY CORRECTION TABLE BY TEMPERATURE
- 3-8. CAPACITY CORRECTION CURVE BY REFRIGERANT PIPING LENGTH
- 3-9. CAPACITY CORRECTION TABLE BY REFRIGERANT PIPING LENGTH
- 3-10. CHARGE CALCULATIONS
- 3-11. AIR FLOW DATA
- 3-12. SOUND PRESSURE LEVELS
- 3-13. STANDARD OPERATION RANGE
- 3-14. MAXIMUM HEATING CAPACITY IN LOW AMBIENT TEMPERATURE
- 3-15. ACCESSORIES
M-Series - MSZ/MUZ-GE-NA Heat Pump Systems (August 2014)
MSZ-GE-NA-15
© 2014 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specication may be subject to change without notice.
Unit: inch
MUZ-GE18NA-1
20-9/32
14-3/16
Air in
11-25/32
2-19/32
Air in
Air out
19-11/16
33-1/16
13
2
4-25/32
33-7/16
16-15/16
3-3/16
4-3/8
×
13/16 slot
1-11/32
1-9/16
Drain 3 holes
(ø1
-5/16)
30°
35°
2-9/16
Liquid:1/4(flared)
Gas :1/2(flared)
3-9/16
8-11/32
Open as a rule
20 inch or more if
the front and both
sides are open
4 inch or more/
8 inch or more if
there are obstacles
to both sides
Open as a rule
20 inch or more if the back,
both sides and top are open
REQUIRED SPACE
14 in. or more
4 in. or more
3-2. EXTERNAL DIMENSIONS