Specification Sheet
Specications are subject to change without notice.
© 2013 Mitsubishi Electric US, Inc.
Notes:
Indoor Unit
MCA ............................................... 1 A
Blower Motor (ECM)............................. 0.76 F.L.A.
Airow
Cooling (Lo - Med - Hi - Powerful) 389 - 639 - 848 - 887 Dry CFM
350 - 576 - 763 - 798 Wet CFM
Sound Pressure Level
Cooling (Lo - Med - Hi - Powerful) .......32 - 42 - 49 - 50 dB(A)
DIMENSIONS UNIT INCHES / MM
W 46-1/16 / 1,170
D 11-5/8 / 295
H 14-3/8 / 365
Weight ....................................40 lbs. / 18 kg
External Finish ......... . . . . . . . . . . . Munsell No. 1.0Y 9.2 / 0.2
Field Drainpipe Size O.D......................5/8" / 15.88 mm
Remote Controller ................................Wireless
Outdoor Unit
Compressor ................ . . . . . . DC Inverter-driven Rotary
MCA .............................................. 21 A
Fan Motor (ECM) ............................... 0.93 F.L.A.
Sound Pressure Level
Cooling ........................................55 dB(A)
DIMENSIONS INCHES / MM
W 33-1/16 / 840
D 13 / 330
H 33-7/16 / 849
Weight ...................................126 lbs. / 57 kg
External Finish ............... . . . . . . .Munsell No. 3Y 7.8 / 1.1
Refrigerant Type ................................... R410A
Refrigerant Pipe Size O.D.
Gas Side ................................5/8" / 15.88 mm
Liquid Side................................3/8" / 9.53 mm
Max. Refrigerant Pipe Length.....................100' / 30 m
Max. Refrigerant Pipe Height Difference .............50' / 15 m
Connection Method .................................Flared
SPECIFICATIONS: MSY-D30NA-8 & MUY-D30NA-1
Cooling*
Rated Capacity...............................30,700 Btu/h
Minimum Capacity .............................9,800 Btu/h
SEER ......................................16.0 Btu/h/W
Total Input ......................................3,380 W
ELECTRICAL REQUIREMENTS
Power Supply ....................208 / 230V, 1-Phase, 60 Hz
Breaker Size........................................25 A
Voltage
Indoor - Outdoor S1-S2 ......................AC 208 / 230V
Indoor - Outdoor S2-S3 ...........................DC ±24V
Indoor - Remote Controller.....................MKH1 DC 3V
PAR-31MAA DC 12V
PAC-YT53CRAU DC 12V
OPERATING RANGE
Indoor Intake Air
Temp.
Outdoor Intake Air
Temp.
Cooling
Maximum
90º F (32º C) DB
73º F (23º C) WB
115º F (46º C) DB
Minimum
67º F (19º C) DB
57º F (14º C) WB
14º F (-10º C) DB
* Rating Conditions per AHRI Standard
Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB
Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB