Spec Sheet

SPECIFICATIONS: MXZ-3C30NA2-U1, contd.
Operating Range:
Outdoor
Indoor Unit Type SEER EER HSPF
(IV)
Cooling 14 to 115° F (−10 to 46° C) DB
19.0 10.6 10.6 3.90 NA
Heating 5 to 65° F (15 to 18° C) WB
NA NA NA NA NA
16.2 9.6 10.6 3.64 NA
Multi-zone Indoor/Outdoor Combination Table
* Refer to indoor unit submittal.
Power supply
Connect wires to the matching numbers of terminals.
Be sure to attach each screw to its correspondent terminal
when securing the cord and/or the wire to the terminal block.
* A disconnect switch should be required. Check the local code.
Use double insulated copper wire with 600 V insulation.
Use copper conductors only.
* Follow local electrical code.
Lead wire
POWER SUPPLY CABLE AND GROUND WIRE
Use solid or stranded conductor Min. AWG12.
Use copper conductors only.
* Follow local electrical code.
Ground
Terminal block
A – C D
Terminal block 1
D unit is for 4C36NA only
Notes:
Specifications are subject to change without notice.
© 2016 Mitsubishi Electric Sales Canada Inc
Page 2 of 3
Form # SB_MXZ-3C30NA2-U1_201905
COP @
47°F
COP
@ 17°F
Non-ducted (*2)
Ducted and
Non-ducted
Ducted (*2)
Terminal block for
indoor/outdoor unit
A – C D
Terminal block
5/8 in.
(15 mm)
1-3/8 in.
(35 mm)
Grounding
terminal **
208/230 VAC
1 phase 60 Hz
Power supply
208/230 VAC
1 phase 2 wires 60 Hz
Disconnect
switch *
Grounding
terminal **
Grounding
terminal **
For future servicing, give extra length to the connecting wires.
Terminal block
OUTDOOR UNIT
Connect the terminal block in
following order.
A
B
C
D
P
D unit is for 4C36NA only
Remark:
Use solid conductor Min. AWG14 or stranded conductor Min.
AWG14.
CONNECTING WIRES AND CONNECTING GROUND WIRE
** Use a ring tongue terminal in order to connect a ground wire to terminal.
INDOOR UNIT
Terminal block
WARNING:
Use the indoor/outdoor unit connecting wire that meets the Stand-
ards to connect the indoor and outdoor units and x the wire to
the terminal block securely so that no external force is conveyed
to the connecting section of the terminal block. An incomplete
connection
or xing of the wire could result in a re.
Indoor - Outdoor Power Connection:
Connecting order
Notes:
Minimum of two Indoor Units must be connected to the MXZ-3C30NA2.
Minimum installed capacity cannot be less than 12,000 Btu/h.
System can operate with only one Indoor Unit turned on.
May connect to any style indoor unit or combination.
Information provided at 208/230V.
Refer to the MXZ-C Technical & Service Manual for detailed specifications and additional information per Indoor Unit Combination.
MVZ CONNECTION RULES:
Only 1 MVZ may be used on any system.
When an MVZ is connected, total connected capacity must be less than 100%.
When an MVZ is connected, no P-Series indoor units can be used (PCA, PLA, or PEAD).
- MXZ Compatibility Chart – available on MESCA Tech Info Centre M-Series submittal page
Should this document be altered or changed without MESCA’s permission, it becomes null and void. MESCA assumes no responsibility for any consequences in such cases.