1-5. INSTALLATION DIAGRAM
Units should be installed by licensed contractor according to
local code requirements.
After the leak test, apply insulat-
ing material tightly so that there is
no gap.
Wh en t he p ip in g is to be a t-
tached to a wall containing metals
(tin plated) or metal netting, use
a ch em ic al ly trea te d wooden
piece 25/32 in. (20 mm) or thicker
between the wall and the piping
or wrap 7 to 8 turns of insulation
vinyltapearoundthepiping.
To use existing piping, perform
COOL operation for 30 minutes
andpump downbeforeremoving
the old air conditioner. Remake
are according to the dimension
for new refrigerant.
PARTS TO BE PROVIDED AT YOUR SITE
(A) Power supply cord* 1
(B) I
ndoor/outdoor unit connecting wire* 1
(C) Extension
pipe 1
(D) W
allholecover 1
(E) Piping
tape 1
(F)
Extension
drain hose (or soft PVC
hose, 19/32 in. (15 mm) inner diam-
eter or hard PVC pipe VP16)
1
(G) Refrigeration
oil
Little
amount
(H) Putty 1
(I) Pipe
xingband 2 to 7
(J) Fixing
screw for (I) 2 to 7
(K) W
allholesleeve 1
* Note:
P
lace indoor/outdoor unit connecting wire (B) and
power supply cord (A) at least 3 ft. (1 m) away from
the TV antenna wire.
The“Q’ty”for(B)to(K)intheabovetableisquan
-
tity
to be used per indoor unit.
More than
3-15/16 in.
(100 mm)
Open as a rule
More than 19-11/16 in.
(500 mm) if the front
and both sides are
open
More
than 3-15/16 in. (100 mm)
More than 7-7/8 in. (200 mm)
if there are obstacles to both
sides
Open
as a rule
More than 19-11/16 in. (500 mm) if the
back, both sides and top are open
More than 13-25/32 in.
(350 mm)
Outdoor unit installation
Air inlet
Air outlet
2-U-shape notched holes
(Base bolt M10)
Unit : inch
2. OUTDOOR UNIT INSTALLATION
2-1. INSTALLING THE UNIT
Fix here with
M10 bolts.
Make the setting
depth deeper.
Make with wider.
Anchor leg
31/32 (25) or less
Anchor bolt length
Anchor bolt pitch
(Unit: inch (mm))
• Besuretoxtheunit’slegswithboltswheninstallingit.
• Besuretoinstalltheunitrmlytoensurethatitdoesnotfallbyanearthquakeoragust.
• Refertothegureintherightforconcretefoundation.
• In case of MXZ-2C20NAHZ, MXZ-3C24/30NAHZ, do not use the drain socket and the drain caps.
• In case of MXZ-5C42NA, do not use the drain socket and the drain caps in the cold region. Drain may freeze and it makes the fan stop.
23-5/8
(600)
14-9/16
(370)
Outdoor unit installation
37-13/32
23-5/8
6-7/8
2 - (15/32 × 1-31/32)
oval
holes(BaseboltM10)
Air inlet
13
14-9/16
16-13/32
Air inlet
Air outlet
2-U-shape notched holes
(Base bolt M10)
Unit : mm
950
600175
2 - 12 × 36
oval
holes(BaseboltM10)
Air inlet
330
370
4
17
BH79A088H01_en.indd 3 2014/08/05 13:34:47