Installation Guide

En-3
1-5. INSTALLATION DIAGRAM
Units should be installed by licensed contractor according to
local code requirements.
After the leak test, apply insulat-
ing material tightly so that there is
no gap.
Wh en t he p ip in g is to be a t-
tached to a wall containing metals
(tin plated) or metal netting, use
a ch em ic al ly trea te d wooden
piece 25/32 in. (20 mm) or thicker
between the wall and the piping
or wrap 7 to 8 turns of insulation
vinyltapearoundthepiping.
To use existing piping, perform
COOL operation for 30 minutes
andpump downbeforeremoving
the old air conditioner. Remake
are according to the dimension
for new refrigerant.
PARTS TO BE PROVIDED AT YOUR SITE
(A) Power supply cord* 1
(B) I
ndoor/outdoor unit connecting wire* 1
(C) Extension
pipe 1
(D) W
allholecover 1
(E) Piping
tape 1
(F)
Extension
drain hose (or soft PVC
hose, 19/32 in. (15 mm) inner diam-
eter or hard PVC pipe VP16)
1
(G) Refrigeration
oil
Little
amount
(H) Putty 1
(I) Pipe
xingband 2 to 7
(J) Fixing
screw for (I) 2 to 7
(K) W
allholesleeve 1
* Note:
P
lace indoor/outdoor unit connecting wire (B) and
power supply cord (A) at least 3 ft. (1 m) away from
the TV antenna wire.
The“Q’ty”for(B)to(K)intheabovetableisquan
-
tity
to be used per indoor unit.
More than
3-15/16 in.
(100 mm)
Open as a rule
More than 19-11/16 in.
(500 mm) if the front
and both sides are
open
More
than 3-15/16 in. (100 mm)
More than 7-7/8 in. (200 mm)
if there are obstacles to both
sides
Open
as a rule
More than 19-11/16 in. (500 mm) if the
back, both sides and top are open
More than 13-25/32 in.
(350 mm)
Outdoor unit installation
Air inlet
Air outlet
2-U-shape notched holes
(Base bolt M10)
Unit : inch
2. OUTDOOR UNIT INSTALLATION
2-1. INSTALLING THE UNIT
Fix here with
M10 bolts.
Make the setting
depth deeper.
Make with wider.
Anchor leg
31/32 (25) or less
Anchor bolt length
Anchor bolt pitch
(Unit: inch (mm))
• Besuretoxtheunit’slegswithboltswheninstallingit.
• Besuretoinstalltheunitrmlytoensurethatitdoesnotfallbyanearthquakeoragust.
• Refertothegureintherightforconcretefoundation.
In case of MXZ-2C20NAHZ, MXZ-3C24/30NAHZ, do not use the drain socket and the drain caps.
In case of MXZ-5C42NA, do not use the drain socket and the drain caps in the cold region. Drain may freeze and it makes the fan stop.
23-5/8
(600)
14-9/16
(370)
Outdoor unit installation
37-13/32
23-5/8
6-7/8
2 - (15/32 × 1-31/32)
oval
holes(BaseboltM10)
Air inlet
13
14-9/16
16-13/32
Air inlet
Air outlet
2-U-shape notched holes
(Base bolt M10)
Unit : mm
950
600175
2 - 12 × 36
oval
holes(BaseboltM10)
Air inlet
330
370
4
17
BH79A088H01_en.indd 3 2014/08/05 13:34:47