MXZ-3C24NAHZ3 Submittal

Specications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
SPECIFICATIONS: MXZ-3C24NAHZ3
test
Cooling
1
(Non-Ducted // Mix // Ducted)
Maximum Capacity BTU/H 23,600 // 23,600 // 23,600
Rated Capacity BTU/H 22,000 // 22,800 // 23,600
Minimum Capacity BTU/H 12,600 // 12,600 // 12,600
Maximum Power Input W 3,770 // 3,770 // 3,770
Rated Power Input W 1,630 // 1,995 // 2,360
Power Factor (208V, 230V) % 98.5, 98.5 // 98.5, 98.5 // 98.5, 98.5
Heating at 47°F
2
(Non-Ducted // Mix //
Ducted)
Maximum Capacity BTU/H 30,600 // 30,600 // 30,600
Rated Capacity BTU/H 25,000 // 24,800 // 24,600
Minimum Capacity BTU/H 11,400 // 11,400 // 11,400
Maximum Power Input W 4,540 // 4,540 // 4,540
Rated Power Input W 1,725 // 1,809 // 1,871
Power Factor (208V, 230V) % 97.3, 97.3 // 97.6, 97.4 // 97.4, 97.6
Heating at 17°F
3
(Non-Ducted // Mix //
Ducted)
Maximum Capacity BTU/H 25,000 // 24,800 // 24,600
Rated Capacity BTU/H 14,000 // 14,000 // 14,000
Maximum Power Input W 3,557 // 3,671 // 3,795
Rated Power Input W 1,622 // 1,629 // 1,635
Heating at 5°F
4
(Non-Ducted // Mix //
Ducted)
Maximum Capacity BTU/H 25,000 // 24,800 // 24,600
Maximum Power Input W 3,760 // 3,980 // 4,200
Efciency (Non-Ducted // Mix // Ducted)
SEER 19.0 // 17.2 // 15.5
EER
1
13.5 // 11.7 // 10.0
HSPF (IV) 10.0 // 9.5 // 9.0
COP at 47°F
2
4.25 // 4.02 // 3.8
COP at 17°F at Maximum Capacity
3
2.06 // 1.95 // 1.9
COP at 5°F at Maximum Capacity
4
1.95 // 2.11 // 1.72
ENERGY STAR
®
Certied Yes // No // No
Electrical
Electrical Power Requirements
Voltage, Phase,
Frequency
208/230, 1, 60
Guaranteed Voltage Range V AC 187-253
Voltage: Indoor - Outdoor, S1-S2 V AC 208/230
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Short-circuit Current Rating (SCCR) kA 5
Recommended Fuse/Breaker Size A 40
Recommended Wire Size AWG 14
Minimum Circuit Ampacity A 30.5
Maximum Overcurrent Protection A 40
Fan Motor Full Load Amperage A 2.43
Outdoor unit
Airow Rate (Cooling / Heating) CFM 2,150 / 2,550
Refrigerant Control LEV
Defrost Method Reverse Cycle
Heat Exchanger Type Plate n coil
Sound Pressure Level, Cooling
1
dB(A) 54
Sound Pressure Level, Heating
2
dB(A) 58
Compressor Type DC INVERTER-driven Twin Rotary
Compressor Model MNB33FBTMC-L
Compressor Rated Load Amps A 20
Compressor Locked Rotor Amps A 28.8
Compressor Oil Type // Charge oz. FV50S // 37.2
Base Pan Heater Built-in
Unit Dimensions
W: In. [mm] 37-13/32 [950]
D: In. [mm] 13 [330]
H: In. [mm] 41-17/64 [1,048]
Package Dimensions
W: In. [mm] 41-3/8 [1,050]
D: In. [mm] 17-3/8 [440]
H: In. [mm] 46-3/4 [1,190]
Unit Weight Lbs.[kg] 189 [86]
Package Weight Lbs.[kg] 212 [96]
Outdoor unit operating temperature
range
Cooling Intake Air Temp (Maximum / Minimum
*A
) °FDB 115 / 14
Cooling Thermal Lock-out / Re-start Temperatures °FDB 10.4 / 14
Heating Intake Air Temp (Maximum / Minimum) °FWB 65 / -13
Heating Thermal Lock-out / Re-start Temperatures °FDB -18 / -14
Refrigerant
Charge Lbs, oz 8.0, 13.0
Chargeless Piping Length Ft. [m] 98.0 [30.0]
Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.216 [20]
NOTES:
AHRI Rated Conditions
1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a xed compressor speed)
2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
Conditions
4
Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
*
Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
*A
5°F DB - 115°F DB when optional wind bafes are installed
For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance.
Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications
where it is known that all connected units will NOT be operating at the same time.