Engineering Manual
A-124
Unit: inch (mm)
SUZ-KA12NA SUZ-KA15NA
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
(with strainer)
Stop valve
(with service port)
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe ø3/8(ø9.52) (KA12)
Refrigerant pipe ø1/2(ø12.7) (KA15)
(with heat insulator)
Refrigerant pipe ø1/4(ø6.35)
(with heat insulator)
R.V. coil
heating ON
cooling OFF
Strainer
#100
Capillary tube
O.D. 0.118 × I.D. 0.071
× 23-5/8
(ø
3.0
× ø
1.8
×
600
)
(×2)
LEV
Ambient
temperature
thermistor
RT65
Muffler
Capillary tube
O.D. 0.118 × I.D. 0.079
× 9-7/16
(ø3.0 × ø2.0
×
240)
Outdoor heat
exchanger
temperature
thermistor
RT68
Muffler
Service port
Service port
SUZ-KA18NA
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
(with strainer)
Stop valve
(with service port)
Capillary tube
O.D. 0.142 × I.D. 0.094
× 1-31/32
(ø
3.6
×
ø
2.4
×
50)
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe
ø
1/2
(ø12.7)
(with heat insulator)
Refrigerant pipe ø1/4(ø6.35)
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Muffler
#100
Receiver
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
Service port
Service port