Engineering Manual

C-1
Outdoor unit
8C60NA-U18C48NA-U15C42NA2-U14C36NA2-U13C30NA2-U13C24NA2-U12C20NA2-U1
Indoor unit
M-series Wall MSZ-FE09NA
Mounted MSZ-FE12NA
MSZ-FH06NA
MSZ-FH09NA
MSZ-FH12NA
MSZ-FH15NA
MSZ-FH18NA2
MSZ-GE06NA
MSZ-GE09NA
MSZ-GE12NA
MSZ-GE15NA
MSZ-GE18NA
MSZ-GE24NA
MSZ-GL06NA
MSZ-GL09NA
MSZ-GL12NA
MSZ-GL15NA
MSZ-GL18NA
MSZ-GL24NA
MSZ-EF09NAW(S)(B)
MSZ-EF12NAW(S)(B)
MSZ-EF15NAW(S)(B)
MSZ-EF18NAW(S)(B)
MSZ-HM09NA
MSZ-HM12NA
MSZ-HM15NA
MSZ-HM18NA
MSZ-HM24NA
1-way MLZ-KP09NA
Cassette MLZ-KP12NA
MLZ-KP18NA
Floor
Standing
MFZ-KJ09NA
MFZ-KJ12NA
MFZ-KJ15NA
MFZ-KJ18NA
Vertical *2
(MultiPosition)
MVZ-A12AA
MVZ-A18AA
MVZ-A24AA
MVZ-A30AA
MVZ-A36AA
S-series
Cassette
SLZ-KA09NA4-way
SLZ-KA12NA
SLZ-KA15NA
Ceiling
Conceald *3 *4
SEZ-KD09NA
SEZ-KD12NA
SEZ-KD15NA
SEZ-KD18NA
Vertical
(MultiPosition)
SVZ-KP12NA
SVZ-KP18NA
P-series
PLA-A18EA
4-way PLA-A12EA
Cassette *5
PLA-A24EA
PLA-A30EA
PLA-A36EA
PLA-A42EA
Ceiling
Suspended
PCA-A24KA
PCA-A30KA
PCA-A36KA
PCA-A42KA
PEAD-A09AA
PEAD-A12AA
PEAD-A15AA
PEAD-A18AA
Ceiling
Conceald *3 *4
PEAD-A24AA
PEAD-A30AA
PEAD-A36AA
PEAD-A42AA
MXZ-
C Series
C. MXZ COMBINATION CHART
MXZ-8C48NA (For each connected branch box)
Number of connecting
multi-position unit
Constraints
2
Any indoor units other than multi-position models
are not connectable.
1
· Only 1 SEZ or 1 PEAD can be included in the
connection.
MXZ-8C60NA (For each connected branch box)
Number of connecting
multi-position unit
Constraints
2
Any indoor units other than multi-position
models are not connectable.
1
·
The total rated capacity (cooling) should be
100% or below including the MVZ-series unit.
· Only 1 SEZ or 1 PEAD can be included in the
connection.
*3 For MXZ-8C60NA; When connecting the SEZ and PEAD-series units, the total rated capacity (cooling) per 1 branch box should be 100% or below including the
SEZ and PEAD-series units. (Only if connecting to PAC-MKA50/51BC)
*4 For MXZ-8C48NA; A branch box can connect to maximum 3 of the SEZ/PEAD-series units. When connecting with 3 of the SEZ/PEAD-series units per 1 branch
box, other inside units cannot be connected.
For MXZ-8C60NA; A branch box can connect to maximum 2 of the SEZ/PEAD-series units. When connecting with 1 and over 1 of the SEZ/PEAD series units,
the total ability including of the SEZ/PEAD is 100% and below 100%.
*5 For MXZ-8C48NA/8C60NA; When the system includes even 1 unit of PLA-A·EA7, the number of the maximum connectable indoor units is decreased as fol-
lows: 6 for MXZ-8C48NA-U1 and MXZ-8C60NA-U1
*1 When operating MXZ-2C20, 3C24, 3C30, 4C36 and 5C42NA2-U1, the total current of indoor units must be 3A or less.
*2
When connecting a multi-position unit(s), set additional constraints as follows. For connections other than those specied below, consult your dealer.