Owner`s manual

61
(4) Selecting the Trigger Method
Manual trigger --
Allows you to apply the trigger manually.
Item trigger --
Allows you to select one or two items and uses the ON or
OFF signal of the item(s) as a trigger to start recording.
(5) Setting the Recording Time
The recording time can be set from 0day 0h 0min to 5days
0h 0min. If you do not wish to set a recording time, press
button without setting the time.
The day and time are set using .
-Day --Unit: 1 day
-Hour-- Unit: 1h, Unit: 5h
-Minute-- Unit: 1min, Unit: 10min
You can also set the time using the slide bars.
(6) Checking the Recording Settings
Check the recording settings and press button to
transmit the data to the SWS monitor cartridge.
A message appears indicating that the recording settings
will be transmitted to the I/F cartridge. Press button.
(7) Recording Using the Drive Recorder
Once the data have been transmitted to the SWS monitor
cartridge, the screen shown at left appears. If the trigger set
was a manual trigger, press button to start recording.
If the trigger set was an item trigger, recording begins when
the set conditions are met.
Note:
To disconnect the SWS monitor cartridge, press button.
The following message appears: “Do you wish to
disconnect the I/F cartridge? (If so, select YES, then wait for
the ready message to appear.)” Once the ready message
appears, disconnect the cartridge.
SWS Monitor