Owner`s manual
42
(8) PC Drive recorder setup
• Please confirm the contents of record setting, and set up
the sampling interval with the cursor or button.
• Select a display format for recording (either Graph or Text)
having a circle marked “ ”.
--Displaying item Select (‘Graph’ only)--to (9)
--OK -- to (10)
Note:
-The sampling interval time indicates the data-recording
interval for one item. A setting of “0 sec” (fastest) results in
the fastest sampling interval.
-Recordable time computes the number of the maximum
record points as 20000 points, and is displayed. This is the
prediction time on calculation and differs from actually
recordable time.
-The configuration of the displayed file names is DR+ Year
MonthDay + Time (military time including seconds), using
the PC time. <DR: The file saved by the drive recorder>
-The setting value of a sampling interval can be chosen
from 0sec(fastest)/1sec/10sec/1min.
(9) Graph display item selection
Select the items you wish to display on the graph.
Selected 4items are displayed during the recording.
The items not selected are not displayed on graph but the
data are recorded.
-- OK -- to (8)
(10) Enter the record information (memo).
Enter the reference information, such as the vehicle model
and diagnosed system name.
--OK -- to (11)
Note:
Because the unit is linked with the PC keyboard, you can
enter the information either directly using the PC keyboard
or by using the screen keyboard.
(11) The contents check of setting (1/3)
The list of recording settings appears.
--To check set items
--To check threshold trigger conditions (if selected)
Pressing starts recording – go to (14)
Drive Recorder <Record on PC >