Owner`s manual

27
(6) Accuracy Check Results
After the Accuracy Check completed normally, the results of
each test is displayed.
5-3-2. Zero-Calibration
(1) When the Accuracy Check is NG, the massage illustrated
on the left will be displayed. Start the procedure for
Zero-calibration in order to retry the Weight Sensor
Accuracy check
--OK to (2)
--Cancel – back to 5-3-1.(4) / (5)
(2) Zero-calibration
Unload weight and remove friction.
Slide the passenger seat to rear end.
Press button and start the Zero-calibration.
(3) Zero-calibration Start Confirmation
--Start
--Cancel --back to (2)
Note:
After the Zero-calibration completed, please retry the
Weight Sensor Accuracy check (5-3-1(4)).
Special Function <Seat Weight Sensor Accuracy Check>
(In the case 0lbs check is NG)
(In the case 66lbs check is NG)