SCM40ZJ-S SCM50ZJ-S1 SCM60ZJ-S1 SCM71ZJ-S1 SCM80ZJ-S1 SCM100ZJ-S1 SCM125ZJ-S1
2 Rooms 2~3 Rooms 2~4 Rooms 4~5 Rooms 4~6 Rooms
Power Supply Outdoor 1 Phase 230V 50Hz
Rated Capacity
Cooling T1 kW 4.0(1.8~5.9) 5.0(1.8~7.1) 6.0(1.8~7.5) 7.1(1.8~8.8) 8.0(1.8~9.2) 10 12.5
Heating H1 kW 4.5(1.4~6.9) 6.0(1.4~7.5) 6.8(1.5~7.8) 8.6(1.5~9.4) 9.3(1.5~9.8) 12 13.5
Electrical Input
Cooling T1 kW 0.84 1.08 1.43 1.74 2.16 2.86 3.9
Heating H1 kW 0.90 1.31 1.51 2.00 2.26 2.93 3.25
EER Cooling T1 4.76 4.63 4.20 4.08 3.70 3.5 3.21
COP Heating H1 5.00 4.58 4.50 4.30 4.12 4.1 4.15
Current
Cooling T1 A 3.7 4.7 6.5 7.6 9.4 12.4 17
Heating H1 A 4 5.8 6.8 8.8 10 12.8 14.1
Rec Circuit Breaker A 25A
Sound Power Level (JIS C9612)
Cooling (Outdoor) dB (A) 60 62 63 65 66 68 69
Heating (Outdoor) dB (A) 62 65 65 66 66 71 72
External Dimensions (HXWXD) mm 640X850X290 750X880X340 945X970X370
Net weight Outdoor kg 47 48 49 62 92
Refrigerant Piping
Liquid Line mm Ø6.35 X 2 Ø6.35 X 3 Ø6.35 X 3 Ø6.35 X 4 Ø6.35 X 4 Ø6.35 X 5 Ø6.35 X 6
Gas Line mm Ø9.52 X 2 Ø9.52 X 3 Ø9.52 X 3 Ø9.52 X 4 Ø9.52 X 4 Ø9.52 X 5 Ø9.52 X 6
Union mm (Ø9.52 Ø12.7) X 1 (Ø9.52 Ø12.7) X 2 (Ø9.52 Ø12.7) X 2 (Ø9.52 Ø12.7) X 2 (Ø9.52 Ø12.7) X 2 (Ø9.52 Ø12.7) X 2
Connection Method Flare connection
Refrigerant R410A
Volume kg 2.0 2.5 3.15 6
Pre-Charged 30 mtrs 40 mtrs 50 mtrs
Indoor Unit Combination
SRK*ZJS/S1
kW
2.0,2.5,3.5 2.0,2.5,3.5,5.0 2.0,2.5,3.5,5.0
SRK*ZJX 2.0,2.5,3.5 2.0,2.5,3.5 2.0,2.5,3.5 2.0,2.5,3.5
SRK*ZJX-S1 5.0 5.0,6.0 5.0,6.0
SRK*ZK-S 7.1
SRF*ZJX 2.5,3.5 2.5,3.5 2.5,3.5
SRF*ZJX-S1 5.0 5.0 5.0
SRR*ZJ 2.5,3.5 2.5,3.5,5.0 2.5,3.5,5.0,6.0
FDTC*VD 2.5,3.5 2.5,3.5,5.0 2.5,3.5,5.0,6.0
FDUM*VF 5.0
FDEN*VF 5.0
Indoor Unit Connection 2 Units 2 to 3 Units 2 to 4 Units 4 to 5 Units 4 to 6 Units
Indoor Connection Capacity kW 4.0kW to 6.0kW 4.0kW to 8.5kW 4.0kW to 11.0kW 4.0kW to 12.6kW 4.0kW to 13.5kW 8.0 kW to 16kW 8.0kW to 19.5kW
Notes
1 Rated data is measured using SRK*ZJX indoor units to match the outdoor unit capacity
2 Currently there is no energy labelling standard for this type of product
3 The kW output capacity, electrical input, current and recommended circuit breaker are indicated at rated kW output capacity. Electrical work must be carried out by a suitably quali ed person and comply to all electrical
standards and local regulations.