Multi Series Inverter Multi-Split System Air Conditioners MHIAA is proudly sponsoring Monika’s Doggie Rescue
Multi Series Inverter Multi-Split System Air Conditioners.
WELCOME A home typically has many areas such as bedrooms, living spaces and study rooms. Therefore, to provide total comfort for your home, a multi-split system is recommended so each room can have its own air conditioner. This can be achieved through a Mitsubishi Heavy Industries inverter multi-split system which delivers optimum heating or cooling for everyone, no matter where they are in the home and no matter what size the room may be.
Compact A Mitsubishi Heavy Industries inverter multi-split system allows 2 to 6 indoor units to be connected to a single outdoor unit. This allows multiple rooms to be conditioned without adding clutter to the exterior of your home. One compact multi-split outdoor unit instead of many outdoor units not only adds to the ascetic appeal your home but can be imperative when there is not much space available, for example, when installing outdoor units on balconies or verandahs.
MULTI CONCEPT Independent Control and Comfort Each indoor unit comes with its own remote allowing the unit to be independently switched on/off and have the temperature adjusted as needed. The conditions of rooms can vary greatly depending on many variables such as the number of occupants or the way the room is used. With a range of comfort, air flow and convenience functions on each indoor unit, you can adjust the settings to match the requirements of a room without affecting other ones.
Easy operation All settings done by tapping touch screen panel Operation mode setting screen Setting temperature screen The operation mode can be selected by simply tapping this button. Operation mode Cooling Dry Auto Fan Heating You can select the desired temperature by tapping the ▲▼ button.
Functions. Filter Allergen SUN Filter Photocatalytic Washable Deodorizing Filter It keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be easily restored simply by cleaning and exposing the filter to the sunlight. Enzyme Filter Allergen Self Clean "HI POWER" Operation The unit can operate continuously in HI POWER mode for 15 minutes. This mode is used to reach the desired temperature quickly.
High Efficiency. DC PAM inverter New inverter control (Vector control) An inverter system has a number of advantages over a constant speed system. Its variable speed compressor outputs can ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner can slow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motor driven so it provides superior performance.
-15°C 50 40 30 20 10 0 -10 -20 +46°C Cooling For the capacities under low temperature conditions, refer to technical manual. Advanced Technology.
3D AUTO Vertical + Horizontal AIR SCROLL. 3 motors make 3 independent controls 3 motors make 3 independent controls 3 motors make 3 independent controls 3 motors make 3 independent controls Programmed air distribution Programmed air distribution 3D AUTO 3D AUTO Applied models Applied mode SRK-ZJX, SRK-ZJ SRK-ZJX, SRK 3D AUTO is a one touch programme. Three motors (one vertical working motor + two horizontal working motors) make three independent air flow controls.
Jet air scroll long reach & silent air flow. FEATURES Aircraft technology was used in the design of the air conditioner’s airflow system Fast Slow Colors in the figure show the air speed. We used the same aerodynamic analysis technology as used in developing jet engines. CFD (computational fluid dynamics) is used for blade shape design and air channels for jet engines. The same technology has been used in our air conditioners.
Clean Air. Allergen Clear System The ‘Allergen Clear system’ suppresses the influence of the allergen caught by the filter by controlling the temperature and humidity. Catching Allergen on the Filter Cooling Operation To make condensing water.
Enzyme Rate of inactivation against allergens collected on the filter H2N- Slack of high order structure 100 Reduction in a molecule 99.9% 93.6% -COOH Inactivation rate(%) Inactivation rate(%) 72.7% Protein structure of allergen Sterilization Mechanism Allergen clear filter A molecule is decomposed Sterilization Mechanism Enzyme 50 Urea Rate of inactivation against allergens collected on the filter H2N- Urea Slack of high order structure Enzyme Reduction in a molecule 99.
Ceiling Concealed Type. Wired Remote Control RC-EX1A RC-E5 RCH-E3 Standard Equipment SRR25~60VF Ceiling concealed type (SRR) Models SRR25ZJ-S, 35ZJ-S, 50ZJ-S, 60ZJ-S Unit:mm 325.4 Content Symbol Control Box D SRR25ZJ-S, 35ZJ-S 30 Model 455 515 (Suspension bolts pitch) E A Gas piping B C D E Liquid piping Drain piping 9.52 3 8" Flare 12.7 1 2" Flare 6.
Ceiling Cassette.
Floor Standing. Wired Remote Control RC-EX1A Wired Remote Control RC-EX1A RC-E5 RC-E5 Wireles RCH-E3 Wireless Remote Control RCH-E3 RCN-TC-24W-ER SRF25~50ZJX SRF25ZJX-S, SRF35ZJX-S, SRF50ZJX-S Sophisticated design With a classy semi flat front panel in chic white, this series fits in all kinds of rooms and creates a relaxing atmosphere. Choice of wall hanging, floor standing or behind gallery installation is available.
RC-EX1A RC-E5 RCH-E3 RCN-KIT3-E Ceiling Concealed Type Medium Static. UM50VF RC-EX1A Wired Remote Control RC-E5 RCH-E3 PRODUCTS Wired Remote Control Wireless Remote RCN-KIT3-E Wireless Remote Control FDUM50VF FDUM50VF RC-EX1A RC-E5 RCH-E3 RCN-KIT3-E FDUM50VF Low profile 280 The height of FDUM50 model is only 280mm. 280 280 Improved servicing Fan unit (impeller and motor) can be pulled out from the right side of the unit. Maintenance is available from the right side or from beneath.
Ceiling Suspended. Wired remote control RCH-E3 RC-E5 Wireless remote control RCN-E-E FDEN50VF Easy installation Increased freedom of a piping layout The refrigerant pipe from the unit can be arranged in three directions, rear, right and up. The drain pipe can be arranged in two directions, left and right. This will allow a free layout of piping for various installation conditions. The unit can only be serviced from below.
Control Options.
Inverter Multi-Split System. SCM-ZJ The multi system allows a single outdoor unit to service up to six indoor units.
mm Union 40 mtrs kW 4.0kW to 6.0kW 4.0kW to 8.5kW 2 to 3 Units 4.0kW to 11.0kW 4.0kW to 12.6kW 5.0 5.0,6.0 2.0,2.5,3.5 3.15 Ø9.52 X 4 Ø6.35 X 4 66 66 10 9.4 4.12 3.70 2.26 2.16 4.0kW to 13.5kW 2.5,3.5,5.0,6.0 2.5,3.5,5.0,6.0 (Ø9.52 Ø12.7) X 2 2 to 4 Units 5.0 2 Units 2.5,3.5 2.0,2.5,3.5,5.0 Flare connection 62 750X880X340 (Ø9.52 Ø12.7) X 2 Ø9.52 X 4 Ø6.35 X 4 66 65 5.0 2.5,3.5,5.0 2.5 (Ø9.52 Ø12.7) X 2 Ø9.52 X 3 Ø6.35 X 3 49 65 63 25A 8.8 7.6 4.30 4.08 2.
Multi System Indoor Unit.
Multi System Indoor Unit.
Inverter Multi Split System.
Inverter Multi Split System.
Dimension Outdoor Unit. 286.4 Dimensions L1 L2 L3 203.1 510 850 Examples of Installation 600 100 100 Unit:mm 14.6 14 476 12 2-16x12 17.9 136.9 65 Dimensions L1 L2 L3 312.5 340 290 312.5 340 43.5 Examples of Installation 103.2 49.6 385.9 50 E D 600 100 100 Unit:mm 14 12 43.5 50 E 49.6 D 13.5 286.4 Models SCM50ZJ-S1, 60ZJ-S1 SCM50ZJ-S1 SCM60ZJ-S1 13.5 Models SCM40ZJ-S, 45ZJ-S SCM40ZJ-S Terminal block 136.9 Service panel Terminal block C A B Service panel 42.7 42.
SPECIFICATIONS 27
Before starting use Heating performance Refrigerant leakage The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well.