Service Manual

41
DATA
8
Model
MXZ-3C24NA MXZ-3C24NA2
Indoor type Non-Duct (06+06+09) Duct (09+09+09)
Item Unit Cooling Heating Cooling Heating
Total
Capacity Btu/h 22,000 25,000 23,600 24,600
SHF
Input kW 1.62 1.75 2.10 1.90
Electrical
circuit
Power supply (V, phase, Hz) 208/230, 1, 60
Input kW 1.554 1.684 1.920 1.780
Comp. current (208/230V) A 7.47 / 6.76 8.1 / 7.32 9.23 / 8.35 8.56 / 7.74
Fan motor current A 0.3 0.3 0.3 0.3
Refrigerant
circuit
Condensing pressure PSIG 395 310 419 345
Suction pressure PSIG 162 101 138 102
Discharge temperature ºF 143 137 155 141
Condensing temperature ºF 116 98 120 106
Suction temperature ºF 59 36 50 34
Comp. shell bottom temp. ºF 137 128 146 131
Ref. pipe length
[Total pipe length for multi-system]
ft 25[75]
Refrigerant charge (R410A) 6lb. 13 oz.
Outdoor
unit
Intake air temperature
DB ºF 95 47 95 47
WB ºF - 43 - 43
Fan speed rpm 720 750 720 750
Air ow CFM 2,287 2,382 2,287 2,382
Model
MXZ-3C30NA MXZ-3C30NA2
Indoor type Non-Duct (09+09+12) Duct (09+09+12)
Item Unit Cooling Heating Cooling Heating
Total
Capacity Btu/h 28,400 28,600 27,400 27,600
SHF
Input kW 2.68 2.15 2.84 2.22
Electrical
circuit
Power supply (V, phase, Hz) 208/230, 1, 60
Input kW 2.614 2.084 2.650 2.090
Comp. current (208/230V) A 12.57 / 11.37 10.02 / 9.06 12.74 / 11.52 10.05 / 9.09
Fan motor current A 0.3 0.3 0.3 0.3
Refrigerant
circuit
Condensing pressure PSIG 432 323 439 323
Suction pressure PSIG 137 97 132 99
Discharge temperature ºF 159 136 165 136
Condensing temperature ºF 122 101 124 101
Suction temperature ºF 49 32 47 32
Comp. shell bottom temp. ºF 145 121 156 128
Ref. pipe length
[Total pipe length for multi-system]
ft 25[75]
Refrigerant charge (R410A) 6 lb.13 oz.
Outdoor
unit
Intake air temperature
DB ºF 95 47 95 47
WB ºF - 43 - 43
Fan speed rpm 720 750 720 750
Air ow CFM 2,287 2,382 2,287 2,382
OBH702C