Service manual
59
-20 -10 0 10 20 30 40
0
10
20
30
40
50
60
70
80
90
100
Temperature( )
Defrost thermistor(RT61)
Ambient temperature thermistor(RT65)
Outdoor heat exchanger temperature thermistor(RT68)
Temperature( )
Discharge temperature thermistor(RT62)
0 102030405060708090100110120
0
100
200
300
400
500
600
700
0 1020304050607080
0
20
40
60
80
100
120
140
160
180
200
Temperature( )
Fin temperature thermistor(RT64)
Resistance(k )
Resistance(k )
Resistance(k )
MUZ-GE50VA
MUZ-GE50VAH
Fin temperature
thermistor/RT64
(CN642)
Ambient temperature
thermistor/RT65
(CN643)
Discharge temperature
thermistor/RT62
(CN641)
Defrost thermistor
/RT61(CN641)
LEV connector (CN724)
DB61
280 - 370 VDC
Front side of unit
230 VAC
Smoothing
capacitor
(C62)
Output to
drive
compressor
(LDU,
LDV,
LDW)
(+)
(-)
Fuse (F701)
T3.15AL250V
Smoothing
capacitor
(C61)
Smoothing
capacitor
(C63)
Fuse (F801)
T3.15AL250V
Fuse (F901)
T3.15AL250V
R.V.coil
(CN721)
230 VAC
Jumper wire for changing
defrost setting (JS)
Output to drive outdoor
fan motor (CN932)
230 VAC
Outdoor heat exchanger
temperature thermistor
/RT68(CN644)
Jumper wire for pre-heat
control setting (JK)
Signal of outdoor fan
motor (CN931)
Heater connector
(CN722)
MUZ-GE•VAH
Back side of unit
LED