Service manual

5
Outdoor model
MUZ-
GE25VA
MUZ-
GE25VAH
MUZ-
GE35VA
MUZ-
GE35VAH
MUZ-
GE42VA
MUZ-
GE42VAH
MUZ-
GE50VA
MUZ-
GE50VAH
MUZ-
GE60VA
MUZ-
GE71VA
Power supply Single phase, 230 V, 50 Hz
Capacity
Rated frequency (Min.-Max.)
Cooling
kW
2.5 (1.1 - 3.5) 3.5 (1.1 - 4.0) 4.2 (0.9 - 4.8) 5.0 (1.4 - 5.5) 6.0 (1.5 - 7.5) 7.1 (2.4 - 8.7)
Heating
3.2 (1.3 - 4.5) 4.0 (1.6 - 5.3) 5.4 (1.4 - 6.0) 5.8 (1.4 - 7.3) 6.8 (2.0 - 9.3) 8.1 (2.2 - 9.9)
Breaker Capacity A 10 16 20
Electrical data
Power input 1 (Total)
Cooling
W
545 865 1,215 1,515 1,760 2,130
Heating 700 955 1,460 1,565 1,770 2,110
Running current
1
(Total)
Cooling
A
2.9 4.2 5.6 6.8 7.8 9.3
Heating 3.7 4.6 6.6 7.0 7.9 9.4
Power factor 1 (Total)
Cooling
%
82 90 94 96 98 99
Heating 82 90 96 97 98
Starting current 1 (Total) A 3.7 4.6 6.6 7.0 7.9 9.4
Coef cient of performance
(COP)
1 (Total)
Cooling 4.59 4.05 3.46 3.30 3.40 3.33
Heating 4.57 4.19 3.70 3.71 3.84 3.83
Compressor
Model
KNB073FFDHC KNB092FFAHC
SNB130FGBHT
SNB130FGBMT SNB172FEKMT
Output W 550 650 900 1,200
Current 1
Cooling
A
2.44 3.56 4.99 6.09 6.59 8.00
Heating 3.20 4.06 5.98 6.32 6.44 8.07
Refrigeration oil (Model) cc 320 (NEO22) 450 (NEO22)
350(FV50S) 400(FV50S)
Fan motor
Model RC0J50-DB RC0J50-EA RC0J60-AA RC0J60-BC
Current 1
Cooling
A
0.24 0.35 0.32 0.84 0.83
Heating 0.27 0.31 0.32 0.93 0.82
Dimensions W × H × D mm 800 × 550 × 285
840 × 850 × 330
840 × 880 × 330
Weight kg 30 33 36 54 50 53
Special remarks
Dehumidi cation Cooling /h 0.2 0.9 1.4 1.8 2.3
Air ow 1
Cooling
High
m
3
/h
- 3,492 3,426
Med. 1,806 1,872 2,940 3,066 3,006
Low 1,170 1,776 1,086 1,740 1,692 1,512
Heating
High 2,106 2,016 2,952 2,892
Med. 1,806 1,776 2,940 2,952 2,892
Low 1,452 1,386 2,142 2,226 2,280
Sound level 1
Cooling
dB(A)
47 50 54 55
Heating 48 51 56 55
Fan speed
Cooling
High
rpm
- 950
Med. 740 810 780 840
Low 490 770 490 480 450
Heating
High 860 870 810
Med. 740 770 780 810
Low 600 610 580 620 650
Fan speed regulator 3 2 3
Refrigerant lling capacity (R410A) kg 0.80 1.15 1.55 1.90
NOTE: Test conditions are based on ISO 5151.
Cooling: Indoor Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C
Heating: Indoor Dry-bulb temperature 20°C
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
Refrigerant piping length (one way): 5 m
1 Measured under rated operating frequency.
SPECIFICATION
3