The standard specifications apply only to the operation of the air conditioner under normal conditions. Since operating condi-
tions vary according to the areas where these units are installed, the following information has been provided to clarify the
operating characteristics of the air conditioner under the conditions indicated by the performance curve.
(1) GUARANTEED VOLTAGE
198 ~ 264 V, 50 Hz
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
(1) Indoor intake air wet-bulb temperature: °C [WB]
}
Cooling
(2) Indoor outlet air wet-bulb temperature: °C [WB]
(3) Outdoor intake air dry-bulb temperature: °C [DB]
(4) Total input: W
(5) Indoor intake air dry-bulb temperature: °C [DB]
}
Heating(6) Outdoor intake air wet-bulb temperature: °C [WB]
(7) Total input: W
Indoor air wet/dry bulb temperature difference on the left side of the following chart shows the difference between the
indoor intake air wet/dry bulb temperature and the indoor outlet air wet/dry bulb temperature for your reference at service.
How to measure the indoor air wet bulb / dry bulb temperature difference
1. Attach at least 2 sets of wet and dry bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets
of wet and dry bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air
speed is high.
2. Attach at least 2 sets of wet and dry bulb thermometers to the outdoor air intake.
Cover the thermometers to prevent direct rays of the sun.
3. Check that the air filter is cleaned.
4. Open windows and doors of room.
5. Press the EMERGENCY OPERATION switch once (twice) to start the EMERGENCY COOL (HEAT) MODE.
6. When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.
7. 10 minutes later, measure temperature again and check that the temperature does not change.
MUZ-GE25VA MUZ-GE25VAH MUZ-GE35VA MUZ-GE35VAH MUZ-GE42VA MUZ-GE42VAH
MUZ-GE50VA MUZ-GE50VAH MUZ-GE60VA MUZ-GE71VA
INDOOR UNIT OUTDOOR UNIT
Wet and dry bulb
thermometers
FRONT VIEW
Wet and dry bulb
thermometers
BACK VIEW
Cooling capacity (
at Rated frequency)
0.9
1.0
1.1
1.2
1.3
1.4
1.5
-10-5 0 5 1015202530354045
Outdoor intake air Dry-bulb temperature(°C)
Capacity correction factors
26
24
20
18
22
Indoor intake air Wet-bulb
temperature( )
10.4
9.5
8.7
8.0
7.2
6.5
5.7
MUZ-GE50VA
MUZ-GE50VAH
MUZ-GE42VA
MUZ-GE42VAH
MUZ-GE35VA
MUZ-GE35VAH
MUZ-GE25VA
MUZ-GE25VAH
Indoor air Wet-bulb temperature
difference (°C)
6.6
6.1
5.6
5.1
4.6
4.2
3.7
8.4
7.7
7.1
6.5
5.9
5.3
4.7
10.2
9.4
8.6
7.9
7.1
6.4
5.7
9.3
8.6
7.9
7.2
6.5
5.8
5.2
9.7
8.9
8.2
7.5
6.8
6.1
5.4
MUZ-GE71VA
MUZ-GE60VA
8-1. CAPACITY AND INPUT CURVES
PERFORMANCE CURVES8