Service manual
24
PERFORMANCE DATA HEAT operation
CAPACITY:3.2(kW)
INPUT:735(W)
OUTDOOR WB(
:
)
INDOOR
-10 -5 0 5 10 15 20
DB(
:
)
Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
15 2.02 478 2.43 573 2.85 647 3.26 698 3.68 742 4.06 764 4.48 779
21 1.92 515 2.30 610 2.72 676 3.10 728 3.52 764 3.90 786 4.30 816
26 1.73 551 2.14 647 2.53 713 2.94 764 3.36 801 3.74 823 4.16 845
CAPACITY:4.0(kW)
INPUT:995(W)
OUTDOOR WB(
:
)
INDOOR
-10 -5 0 5 10 15 20
DB(
:
)
Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
15 2.52 647 3.04 776 3.56 876 4.08 945 4.60 1005 5.08 1035 5.60 1055
21 2.40 697 2.88 826 3.40 915 3.88 985 4.40 1035 4.88 1065 5.38 1104
26 2.16 746 2.68 876 3.16 965 3.68 1035 4.20 1085 4.68 1114 5.20 1144
MSZ-FA25VA : MUZ-FA25VA MUZ-FA25VAH Rated frequency 77Hz
MSZ-FA35VA : MUZ-FA35VA MUZ-FA35VAH Rated frequency 73Hz
NOTE Q:Total capacity (kW) INPUT:Total power input (W) DB : Dry-bulb temperature WB : Wet-bulb temperature
OB372D--1qxp 07.5.7 4:36 PM Page 24