Service manual

27
Check of PLASMA AIR PURIFYING power
G
When PLASMA/WASH lamp flashes 2-time.
When POWER lamp flashes 1 to 5 times while PLASMA DEODORIZING / PLASMA AIR PURIFYING power failure
mode is recalled.
After performing the check, make sure to release the failure mode recall function.
Make sure that the front panel is firmly closed. (Refer to 9-1.6 
Figure 5)
1 While pressing both OPERATION SELECT 
button and TOO COOL button on the remote controller at the 
same time, press RESET button.
2 First, release RESET button.
And release the other two buttons after all LCD except the set 
temperature in operation display section of the remote 
controller is displayed after 3 seconds.
3 Press OPERATE/STOP (ON/OFF) button (the set temperature 
is displayed)
4 And press PLASMA button twice with the remote controller 
headed towards the indoor unit. w1
PLASMA AIR PURIFYING operation is selected.
wThe plasma power operation check mode is set.(Refer to 9-2.5.)
PLASMA AIR PURIFYING power supply is normal.
Working of SAFETY DEVICE (PLASMA UNIT)
due to uncomplete close of the front panel could 
cause 2-time flash.
Abnormal discharge may occur due to much dirt on 
the PLASMA unit, clean the unit.
After cleaning, make sure to attach the unit since it is
completely dry.
If PLASMA AIR PURIFYING power operation check is
performed with the plasma unit wet, protection gets active 
and PLASMA/WASH lamp blinks continuously as well.
w2Turn PLASMA AIR PURIFYING power OFF and ON again.
(For turning OFF PLASMA AIR PURIFYING power, refer to 9-2.3.)
(If it goes normal without turning OFF and ON, PLASMA/WASH lamp
doesn't go OFF.)
Yes
No
No
Yes
Yes
No
9.5V DC is generated.
Yes
No
Replace the indoor electronic control P.C. board,
after check of the wiring of CN1T1 on the indoor electronic
control P.C. board.
High voltage (approx. -3.9kV) is generated during PLASMA 
AIR PURIFYING power operation.
Pay careful attention and never touch PLASMA unit and the
high-voltage lead part (red wire).
Yes
No
OFF
Continuously blinking.
OFF
Continuously blinking.
Does PLASMA/WASH lamp 
flash 2-time with unit stopping?
Turn ON the power supply.
Replace the indoor electronic control P.C. board.
Remove PLASMA AIR PURIFYING filter, 
firmly close the front panel, and then perform 
PLASMA AIR PURIFYING power operation 
check (w2).
Does PLASMA/WASH lamp stay OFF, or
continuously blink?
Does PLASMA/WASH lamp stay OFF, or
continuously blink?
Turn OFF the power supply, and check the
SAFETY DEVICE(PLASMA UNIT).
Is it firmly fixed?
Work and Not-work the SAFETY DEVICE
(PLASMA UNIT) using something like a screw 
driver, and measure the resistance between 
CN1T2 1 and 3 on the indoor electronic 
control P.C. board. Does the SAFETY 
DEVICE function?
Keep the SAFETY DEVICE(PLASMA UNIT)
Not-work (close) using something like a screw
driver. Turn ON the power supply. Is the voltage
between CN1 1(+) and 2(GND)
on the PLASMA POWER P.C. board 
(PLASMA AIR PURIFYING) 0V with the unit 
stopping? (Refer to 9-7.)
Set the plasma power failure mode recall function.
(Refer to 9-2.2)
Replace the PLASMA POWER P.C. board 
(PLASMA AIR PURIFYING).
Replace the indoor electronic control P.C. board.
When PLASMA AIR PURIFYING power turns
ON by pressing PLASMA button twice, is there 
12.5V DC between CN11(+) and 2(GND)?
Replace the SAFETY DEVICE(PLASMA UNIT).
Firmly fix the SAFETY DEVICE(PLASMA UNIT).
PLASMA 
AIR PURIFYING
operation
w1 Regardless of normal or abnormal, a short
beep is emitted once as the signal is received.
OB416_--1qxp 12/2/05 4:28 PM Page 27