Service manual
4
SPECIFICATION
3
Indoor model
Function
Power supply
Air flow
(High/Med./Low)
Running current
Power input
Auxiliary heater
Power factor
Fan motor current
Model
Winding
resistance(at 20:)
Dimensions WOHOD
Weight
Air direction
Sound level
(High/Med./Low)
Fan speed
(High/Med./Low)
Fan speed regulator
Thermistor RT11(at 25:)
Thermistor RT12(at 25:)
Remote controller model
MS-A24ND
0.37
81
Electrical
data
Fan
motor
Special
remarks
Capacity
Cooling
Single phase
220-230V, 60Hz
—
100-95
0.37
RC4V40-AA
WHT-BLK 138.2
RED-BLK 159.0
1,100O325O258
16
5
3
10
10
KP0B / KM04B
MS-A18ND
948/762/576
45/40/34
1,220/1,020/810
MS-A30ND
K /h
A
W
A(kW)
%
A
"
mm
kg
dB
rpm
k"
k"
948/834/714
45/41/37
1,220/1,100/970
948/804/660
45/41/37
1,220/1,070/910
NOTE:Test conditions are based on ISO 5151 / SSA 385
Cooling : Indoor DB27°C WB19°C / DB29°C WB19°C
Outdoor DB35°C WB24°C / DB46°C WB24°C
Indoor-Outdoor piping length : 5 / 7.5 m
OB404A--1.qxp 06.4.26 6:01 PM Page 4