Service manual

12
Indoor model
Function
Indoor unit power supply
Air flow (High/Med./Low)
Power outlet
Running current
Power input
Power factor
Starting current
Fan motor current
Model
Winding
resistance(at 20:)
Dimensions WOHOD
Weight
Air direction
Sound level
(High/Med./Low)
Fan speed
(High/Med./Low)
Fan speed regulator
Thermistor RT11 (at 25:)
Thermistor RT12 (at 25:)
Outdoor model
Capacity
Dehumidification
Outdoor air flow
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Compressor motor current
Fan motor current
Model
Output
Winding
resistance (at 20:)
Model
Winding
resistance (at 20:)
Dimensions WOHOD
Weight
Sound level
Fan speed
Fan speed regulator
Refrigerant filling
capacity (R410A)
Refrigerating oil (Model)
K /h
A
A
W
%
A
A
"
mm
kg
dB
rpm
k"
k"
kW
R/h
K /h
A
A
W
A(kW)
%
A
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
MSC-A07WV -
E1
Cooling
Single phase
230V,50Hz
474/372 /276
10
0.17
35
90
0.17
RC4V19-LA
WHT-BLK 413
BLK-RED 334
815O278O217
9
5
36/31 /25
900/750 /600
3
10
10
MUX-A10WV -
E1
Single phase
230V,50Hz
1,914
10
21
0.29
RN092VHSHT
600
C-R 3.87
C-S 6.14
RA6V33-FC
WHT-BLK 223
BLK-RED 221
780O540O255
35
49
825
1
0.90 (Room A+B)
350 (NEO22)
Single
A or B
2.4
0.9
3.20
725
98.5
2.91
3.16
Single
A
3.5
1.4
5.73
1,280
97.1
5.16
2.65
Double
A+B
3.5+2.4
1.4+0.9
8.96
2,005
97.3
8.39
2.84
Double
A+B
1.4O2
0.2O2
3.25
730
97.7
2.96
3.50
MSC-A07WV -
E1
Cooling
Single phase
230V,50Hz
474/372 /276
10
0.17
35
90
0.17
RC4V19-LA
WHT-BLK 413
BLK-RED 334
815O278O217
9
5
36/31 /25
900/750 /600
3
10
10
MUX-A19WV -
E1
Single phase
230V,50Hz
MSC-A12WV -
E1
Electrical
data
Fan
motor
Special
remarks
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity
Coefficient of performance (C.O.P)
Outdoor unit power supply
Indoor unit No.
Capacity
w
w
ww
w
w
Cooling
Single phase
230V,50Hz
582/444 /324
10
0.19
40
92
0.19
RC4V19-KA
WHT-BLK 316
BLK-RED 299
815O278O217
10
5
40/33 /26
930/760 /600
3
10
10
Single
B
2.4
0.9
2,460
20
3.51
785
97.2
48
2.94
0.57
2.93
MC1 : RN145VHSHT, MC2 : RN092VHSHT
MC1 : 1,000, MC2 : 600
RA6V60-GA
WHT-BLK 90
BLK-RED 146
840O640O330
66
52
730
1
1.00 (Room A)
0.80 (Room B)
MC1 : 620 (NEO22), MC2 : 350 (NEO22)
C-R 2.43
C-S 3.80
MC1 : , MC2 :
C-R 3.87
C-S 6.14
w
ww
w
w
ww
w
w
ww
ww
ww
w
ww
NOTE: Test conditions are based on ISO 5151.
Cooling : Indoor DB27°C WB19°C Heating : Indoor DB20°C
Outdoor DB35°C WB24°C Outdoor DB 7°C/WB 6°C
Indoor-Outdoor piping length 5m
w Reference value
OB307A1.qxp 03.2.19 3:57 PM Page 12