Easy Setup
2.2.9 Start command and frequency (speed) setting method
Select an input method of start command and frequency (speed) setting.
Changing parameter
Parameters related to "Start Command and Frequency (Speed) Setting Method". (Refer to the Inverter Instruction Manual for
details of the parameters.)
No. Name Function and description
A
Start Command Input
Method
Select the start command input method of the inverter.
B
Frequency (Speed)
Setting Input Method
Select the frequency (speed) setting input method of the inverter.
C
Next> Proceeds to "Parameter List" (Refer to page 59).
D
<Back Returns to "Motor Setting" (Refer to page 56).
E
Cancel Closes Easy Setup with the invalid setting.
F
Help Displays Help window. (Refer to page 160)
Parameter
Number
Name
79 Operation mode selection
338 Communication operation command source
339 Communication speed command source
340 Communication startup mode selection
B
A
D
CEF