Instruction manual

49
Easy Setup
2
WHEN USING FOR THE FIRST TIME
2.2.2 Communication setting
Adjust the communication setting between a personal computer and inverter.
When communicating with inverter using an USB port of the personal computer, select "USB" in "PC side Port" field, and click
.
When communicating with inverter using a serial port of the personal computer, select "RS-232C" in "PC side P
ort" field.
POINT
Default communication setting is matching to an initial value of inverter.
Check the personal computer side port (serial/USB) and personal computer port number (1 to 63).
No. Name Function and description
Initial
value
A
PC side Port
RS-
232C
Select the communication port from RS-232C or USB. (USB communication is only
available with FR-A700, A701 and E700(SC)(NC) series.)
B
Port Number 1
Select the personal computer communication port number. (Refer to page 50)
C
Through None
Select when connecting through GOT.
D
Communication Speed 19200
Set the communication speed. (Refer to Pr. 118, Pr. 332)
E
Data Length 8
Set the data bit length. (Refer to Pr. 119, Pr. 333)
F
Parity Even
Specify the parity bit. (Refer to Pr. 120, Pr. 334)
G
Stop Bit 2
Set the stop bit length. (Refer to Pr. 119, Pr. 333)
H
Delimiter CR
Specify the delimiter of the data end. (Refer to Pr. 124, Pr. 341)
I
Advanced Displays "Advanced" window. Setting of TimeOut and Retry Count is available.
J
Default Value
Restores default value of communication setting.
K
Next > Proceeds to "Inverter Setting Method" (Refer to page 51).
L
<Back Returns to "System Setting" (Refer to page 48).
M
Cancel Closes Easy Setup with the invalid setting.
N
Help Displays Help window. (Refer to page 160)
G
H
E
A
L
K
J
F
M
N
D
I
B C