Instruction manual

13
1
OUTLINE
Connection and Parameter Setting
(4) Communication through GOT (USB / Serial communication) (Refer to page 23)
Connect to RS-485 terminal through GOT (Display). RS-422 communication unit is necessary for GOT. The number of
connectable inverters depends on the GOT. Refer to GOT1000 series connection manual for details of RS-422
connection and compatible version of GOT.
Note
Taking out and putting in the USB cable while FR Configurator is working may cause the inverter not to be recognized.
Perform taking out and putting in the USB cable for some times, or perform inverter reset (reset GOT when
communication through GOT) with the USB cable connected to PC.
RS-422
USB/Serial
cable
USB connector/
Serial port
GOT1000
The number of connectable
inverters depends on the GOT.
RS-485 terminal block
GOT RS-422
Communication
unit
Personal computer
(FR Configurator)