158
Machine Analyzer (Monitor Area) (FR-A700, A701 with Vector Control)
(5) When Machine Analyzer is started, the following screen appears so that you can check the Machine Analyzer progress
conditions.
• Guideline of oscillation time
Click [Cancel] button to stop the Machine Analyzer Operation, and return to the Machine Analyzer window.
The following screen appears if the motor rotation stroke exceeds the permissible range or the motor speed exceeds 3000r/min
during oscillation.
Click [OK] button to return to the Machine Analyzer setting window.
• If the motor rotation stroke exceeds the permissible range
• If the motor speed exceeds 3000r/min
(6) On completion of Machine Analyzer, the frequency characteristics are displayed on the Machine Analyzer window.
Step Oscillation Time
Step 1 Approx. 0.5s
Step 2 Approx. 1s
Step 3 Approx. 4s
Analysis Approx. 15s
REMARKS
During oscillation, oscillation can be stopped with [Cancel] button, MRS signal (output stop signal) or the parameter unit
[STOP] key.