Machine Analyzer (Monitor Area) (FR-A700, A701 with Vector Control)
4
FUNCTION
(3) Press button to display a message to confirm that the operation is at a stop. Check that the operation status is at
a stop, and click [OK].
The following screen appears when the "Vertical Axis Mode" is selected.
Click [Cancel] button to return to the Machine Analyzer setting window.
Click [OK] button to display the Machine Analyzer Operation start window.
(4) Click [OK] button in the Machine Analyzer Operation screen to start the operation.
Machine Analyzer Operation window
Click [Cancel] button to return to the Machine Analyzer window.
REMARKS
• "Stml condition".................................. The following screen appears if either or both "% of rated Torque" and "Stroke" are set
outside of the setting ranges.
Click [OK] button to return to Machine Analyzer setting window.
Note
• When Machine Analyzer is executed in the vertical shaft mode, a servo lock is first placed, and "Operation ready 2" signal is
output, and then the motor is started in 0.5s.
• When an electromagnetic brake is used, assign the "Operation ready 2" signal to any of the output terminals and modify the
circuit to open the electromagnetic brake using this signal. If this is not done, a machine drop or an overcurrent or similar alarm
may occur. (For details of Pr. 190 to Pr. 196 "output terminal function selection", refer to the Instruction Manual of the inverter.)